1,721,006 research outputs found

    The Patellar Resurfacing in Total Knee Prosthesis: Indications for Bone Stock and Patellar Morphology

    No full text
    The patellar resurfacing is still a controversial and unresolved problem. The choice to use the patellar resurfacing in the total knee prosthesis (TKP) is decided by the surgeon's experience; he analyzes the thickness, the shape, consumption of the surface and he chooses the use of patellar resurfacing or to limit itself to cheiloplasty, denervation, or often to the release of the lateral wing ligament. He also assesses the metabolic state of the bone linked to Osteoporosis and the potential fragility of the joint and kneecap in particular. Bone loss after total knee arthroplasty (TKP) may lead to periprosthetic fractures that are associated with significant costs (morbidity, economic, etc.) and pose a challenge to operative fixation. The literature doesn't express a definitive judgment on the two options, since the results can be overlapped on average. Each option has advantages and disadvantages to be considered in the overall balance of the patellar operation. In reality, however, this technical choice requires more consolidated decision-making criteria so as to minimize the incidence of post-surgical femoral-patellar pain syndrome, the second cause of failure, which frequently leads to revision of the implant. The balance between experience and evidence can be a compromise in the choice of surgery. The experience documented in the literature must identify the parameters capable of constructing an algorithm aimed not only at the secondary resurfacing rate, but at the overall clinical evaluation. This has implications also for the rehabilitation of these patients after surgery

    Accuracy of coracoid bone graft placement: Open versus arthroscopic latarjet

    No full text
    Purpose The aim of this study was to compare the accuracy of the coracoid bone graft placement with the open Latarjet-Patte and arthroscopic Latarjet (arthro-Latarjet) procedures in the treatment of anterior instability of the shoulder. Methods Forty-six patients affected by anterior shoulder instability were divided into two groups. In group A (n = 25), patients were operated by arthroscopic Latarjet (arthro-Latarjet) procedure and in group B (n = 21), patients were operated by open Latarjet-Patte procedure. Instrumental investigation was based on three-dimensional computed tomography (3D-CT) at a minimum 1-year follow-up. Graft placement and integration, divergence and posterior protrusion of the screws, and glenohumeral osteoarthritis were considered as outcomes. Statistical analysis was performed with chi-square or Fisher’s exact test. Significance was set at p < 0.05. Results Positioning of the coracoid graft proved to be optimal in 76% (19/25) of patients of group A and in 100% (21/21) of patients of group B (Fisher’s exact test, p = 0.025). Screw placement with respect to the glenoid surface showed a posterior divergence in 44% (11/25) of patients in group A and in 24% (5/21) of patients in group B (p = 0.15). Posterior protrusion of screw was observed in 76% (19/25) of patients in group A and 71.4% (15/21) of patients in group B (p = 0.73). Graft integration was present in 76% (19/25) of patients in group A and 85.7% (18/21) of patients in group B (Fisher’s exact test, p = 0.48). Mild signs of glenohumeral osteoarthritiswere observed in 12% (3/25) of patients in group A and 28.6% (6/21) of patients in group B (Fisher’s exact test, p = 0.26). Conclusion Patients operated with open Latarjet-Patte procedure showed better results than those of the arthro-Latarjet group in reference to the positioning of the graft on the coronal plane (p = 0.025). No significant differences between the groups were observed for graft integration, divergence of the screws, posterior protrusion of the screws, and osteoarthritis. Level of Evidence Level II, nonrandomized prospective comparative study
    corecore