289 research outputs found
Partial and differential verification in diagnostic accuracy studies Abstract [Oral: O06-1]
Early prediction of pathologic response to neoadjuvant therapy in breast cancer: Systematic review of the accuracy of MRI
Magnetic resonance imaging (MRI) has been proposed to have a role in predicting final pathologic response when undertaken early during neoadjuvant chemotherapy (NAC) in breast cancer. This paper examines the evidence for MRI's accuracy in early response prediction. A systematic literature search (to February 2011) was performed to identify studies reporting the accuracy of MRI during NAC in predicting pathologic response, including searches of MEDLINE, PREMEDLINE, EMBASE, and Cochrane databases. 13 studies were eligible (total 605 subjects, range 16-188). Dynamic contrast-enhanced (DCE) MRI was typically performed after 1-2 cycles of anthracycline-based or anthracycline/taxane-based NAC, and compared to a pre-NAC baseline scan. MRI parameters measured included changes in uni- or bidimensional tumour size, three-dimensional volume, quantitative dynamic contrast measurements (volume transfer constant [Ktrans], exchange rate constant [k(ep)], early contrast uptake [ECU]), and descriptive patterns of tumour reduction. Thresholds for identifying response varied across studies. Definitions of response included pathologic complete response (pCR), near-pCR, and residual tumour with evidence of NAC effect (range of response 0-58%). Heterogeneity across MRI parameters and the outcome definition precluded statistical meta-analysis. Based on descriptive presentation of the data, sensitivity/specificity pairs for prediction of pathologic response were highest in studies measuring reductions in Ktrans (near-pCR), ECU (pCR, but not near-pCR) and tumour volume (pCR or near-pCR), at high thresholds (typically >50%); lower sensitivity/specificity pairs were evident in studies measuring reductions in uni- or bidimensional tumour size. However, limitations in study methodology and data reporting preclude definitive conclusions. Methods proposed to address these limitations include: statistical comparison between MRI parameters, and MRI vs other tests (particularly ultrasound and clinical examination); standardising MRI thresholds and pCR definitions; and reporting changes in NAC based on test results. Further studies adopting these methods are warranted
Meta-analysis of agreement between MRI and pathologic breast tumour size after neoadjuvant chemotherapy
Background:Magnetic resonance imaging (MRI) has been proposed to guide breast cancer surgery by measuring residual tumour after neoadjuvant chemotherapy. This study-level meta-analysis examines MRI's agreement with pathology, compares MRI with alternative tests and investigates consistency between different measures of agreement.Methods:A systematic literature search was undertaken. Mean differences (MDs) in tumour size between MRI or comparator tests and pathology were pooled by assuming a fixed effect. Limits of agreement (LOA) were estimated from a pooled variance by assuming equal variance of the differences across studies.Results:Data were extracted from 19 studies (958 patients). The pooled MD between MRI and pathology from six studies was 0.1 cm (95% LOA: -4.2 to 4.4 cm). Similar overestimation for MRI (MD: 0.1 cm) and ultrasound (US) (MD: 0.1 cm) was observed, with comparable LOA (two studies). Overestimation was lower for MRI (MD: 0.1 cm) than mammography (MD: 0.4 cm; two studies). Overestimation by MRI (MD: 0.1 cm) was smaller than underestimation by clinical examination (MD: -0.3 cm). The LOA for mammography and clinical examination were wider than that for MRI. Percentage agreement between MRI and pathology was greater than that of comparator tests (six studies). The range of Pearson's/Spearman's correlations was wide (0.21-0.92; 16 studies). Inconsistencies between MDs, percentage agreement and correlations were common.Conclusion:Magnetic resonance imaging appears to slightly overestimate pathologic size, but measurement errors may be large enough to be clinically significant. Comparable performance by US was observed, but agreement with pathology was poorer for mammography and clinical examination. Percentage agreement can provide supplementary information to MDs and LOA, but Pearson's/Spearman's correlation does not provide evidence of agreement and should be avoided. Further comparisons of MRI and other tests using the recommended methods are warranted
Meta-analysis of magnetic resonance imaging in detecting residual breast cancer after neoadjuvant therapy
Background It has been proposed that magnetic resonance imaging (MRI) be used to guide breast cancer surgery by differentiating residual tumor from pathologic complete response (pCR) after neoadjuvant chemotherapy. This meta-analysis examines MRI accuracy in detecting residual tumor, investigates variables potentially affecting MRI performance, and compares MRI with other tests.MethodsA systematic literature search was undertaken. Hierarchical summary receiver operating characteristic (HSROC) models were used to estimate (relative) diagnostic odds ratios ([R]DORs). Summary sensitivity (correct identification of residual tumor), specificity (correct identification of pCR), and areas under the SROC curves (AUCs) were derived. All statistical tests were two-sided.ResultsForty-four studies (2050 patients) were included. The overall AUC of MRI was 0.88. Accuracy was lower for "standard" pCR definitions (referent category) than "less clearly described" (RDOR = 2.41, 95% confidence interval [CI] = 1.11 to 5.23) or "near-pCR" definitions (RDOR = 2.60, 95% CI = 0.73 to 9.24; P = .03.) Corresponding AUCs were 0.83, 0.90, and 0.91. Specificity was higher when negative MRI was defined as contrast enhancement less than or equal to normal tissue (0.83, 95% CI = 0.64 to 0.93) vs no enhancement (0.54, 95% CI = 0.39 to 0.69; P = .02), with comparable sensitivity (0.83, 95% CI = 0.69 to 0.91; vs 0.8, 95% CI = 0.80 to 0.92; P = .45). MRI had higher accuracy than mammography (P = .02); there was only weak evidence that MRI had higher accuracy than clinical examination (P = .10). No difference in MRI and ultrasound accuracy was found (P = .15).ConclusionsMRI accurately detects residual tumor after neoadjuvant chemotherapy. Accuracy was lower when pCR was more rigorously defined, and specificity was lower when test negativity thresholds were more stringent; these definitions require standardization. MRI is more accurate than mammography; however, studies comparing MRI and ultrasound are required
Reuse and redesign of suburban office buildings into assisted elderly housing : can it be done?
Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Urban Studies and Planning, 1992.Includes bibliographical references (leaves 95-96).by James L. Roberti.M.S
Conflicts of Interest in Clinical Practice Guidelines: Accelerating an Evolution. An Endocrine Society Consensus Statement.
An analysis of the Endocrine Society\u27s clinical practice guidelines (CPGs) published from 2010 to 2017-presented by Irwig et al. in the current issue of The Journal of Endocrinology and Metabolism-suggested that the Endocrine Society met five of seven National Academy of Medicine (NAM) standards concerning financial conflicts of interest in CPGs. As current contributors to the Endocrine Society\u27s CPG efforts, we offer additional context related to the 2011 NAM standards and the current environment concerning industry support in medicine, and we comment on the nature of industry support received by the Society\u27s CPG authors according to Irwig and colleagues\u27 analysis of the Centers for Medicare and Medicaid Services\u27 Open Payments database. Perhaps most importantly, we outline the Society\u27s recent and ongoing efforts to enhance the value of its CPGs. Such efforts include a 2016 revision of CPG author conflict of interest rules-a change that was invisible to the investigatory methods used by Irwig et al.-in addition to other processes designed to enhance CPG objectivity. We conclude our commentary by recognizing that good-faith attempts to enhance transparency and to reduce conflicts of interest (real or apparent) in CPGs will ultimately serve the best interests of patients and providers; we confirm the Endocrine Society\u27s resolute commitment to providing high-quality, evidence-based clinical guidance via a CPG development process that faithfully accords with current CPG best practices
Use of antenatal services and delivery care in Entebbe, Uganda: a community survey.
BACKGROUND: Disparities in perinatal health care occur worldwide. If the UN Millennium Development Goals in maternal and child health are to be met, this needs to be addressed. This study was conducted to facilitate our understanding of the changing use of maternity care services in a semi-urban community in Entebbe Uganda and to examine the range of antenatal and delivery services received in health care facilities and at home. METHODS: We conducted a retrospective community survey among women using structured questionnaires to describe the use of antenatal services and delivery care. RESULTS: In total 413 women reported on their most recent pregnancy. Antenatal care attendance was high with 96% attending once, and 69% the recommended four times. Blood pressure monitoring (95%) and tetanus vaccination (91%) were the services most frequently reported and HIV testing (47%), haematinics (58%) and presumptive treatment for malaria (66%) least frequently. Hospital clinics significantly outperformed public clinics in the quality of antenatal service. A significant improvement in the reported quality of antenatal services received was observed by year (p < 0.001). Improvement in the range and consistency of services at Entebbe Hospital over time was associated with an increase in the numbers who sought care there (p = 0.038). Although 63% delivered their newborn at a local hospital, 11% still delivered at home with no skilled assistance and just under half of these women reported financial/transportation difficulties as the primary reason. Less educated, poorer mothers were more likely to have unskilled/no assistance. Simple newborn care practices were commonly neglected. Only 35% of newborns were breastfed within the first hour and delayed wrapping of newborn infants occurred after 27% of deliveries. CONCLUSION: Although antenatal services were well utilised, the quality of services varied. Women were able and willing to travel to a facility providing a good service. Access to essential skilled birth attendants remains difficult especially for less educated, poorer women, commonly mediated by financial and transport difficulties and several simple post delivery practices were commonly neglected. These factors need to be addressed to ensure that high quality care reaches the most vulnerable women and infants
Modelling the overdiagnosis of breast cancer due to mammography screening in women aged 40 to 49 in the United Kingdom
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, andreproduction in any
medium, provided the original work is properly cited
- …
