53 research outputs found

    Comparative evaluation of plasma biomarkers of Schistosoma haematobium infection in endemic populations from Burkina Faso

    No full text
    Infection with Schistosoma haematobium causes urogenital disease associated with organ disfunction, bleeding, pain, and higher susceptibility to infections and cancer. Timely and accurate diagnosis is crucial for prompt and appropriate treatment as well as surveillance efforts, and the use of plasma biomarkers offers important advantages over parasitological examination of urine, including increased sensitivity and the possibility to use the same specimen for multiple investigations. The present study aims to evaluate the diagnostic performance of different plasma biomarkers in endemic populations from Burkina Faso, West Africa. Schistosoma spp. Circulating Anodic Antigen (CAA), cell free S. haematobium DNA (cfDNA), class M and G antibodies against S. haematobium Soluble Worm Antigen Preparation (SWAP) and Soluble Egg Antigen (SEA) were measured in 406 plasma samples. Results of each biomarker test were compared to those of CAA, a Composite Reference Standard (CRS) and Latent Class Analysis (LCA). An identical proportion of positive samples (29%) was observed as a result of CAA and cfDNA testing, with a substantial agreement (84%, Cohen k = 0.62) between the results of the two tests, and a comparable agreement with the results of CRS and LCA. A higher positivity was observed, as expected, as a result of specific antibody testing (47%-72%), with IgG showing a higher agreement than IgM with the three references. Also, higher IgG levels were observed in current vs past infection, and ROC analysis identified optimal cutoff values for improved testing accuracy. This study provides compelling evidence that can inform the choice of the most appropriate diagnostic plasma biomarker for urogenital schistosomiasis in endemic areas, depending on the purpose, context, and available resources for testing. Either CAA or cfDNA testing can be used for the diagnosis of patients and for epidemiological investigations, even in absence of urine filtration microscopy, whereas anti-SWAP or anti-SEA IgG can be employed for surveillance and integrated monitoring of control interventions against poverty-associated diseases

    Closing the diagnostic gap in male genital schistosomiasis (MGS): current detection tools and novel strategies.

    No full text
    Male genital schistosomiasis (MGS), a gender-specific manifestation of urogenital schistosomiasis and neglected tropical disease, typically results from the entrapment of Schistosoma haematobium eggs within the male genital tract. Across the world, there are no current and accurate estimates of the burden of MGS, due to disease underreporting primarily from diagnostic challenges and a lack of general awareness within the health system. Diagnostic methods for MGS are extremely limited. Conventionally, semen microscopy for Schistosoma ova is used though this technique suffers from low sensitivity and lacks protocol standardization. The introduction of molecular diagnostics, such as polymerase chain reaction (PCR), has partly helped overcome this challenge of low sensitivity, though may not be suitable for use in resource-constrained settings. To address these challenges, in this review, we propose a two-step diagnostic algorithm for MGS in accordance with recent WHO guidelines, consisting of a high sensitivity serological test followed by a high specificity test (microscopy or molecular assay, dependent on setting). Further investigation is required into standardization of sample collection, processing, storage, and analysis in order to identify an evidence-based optimal diagnostic pipeline. New diagnostic tools are needed such as isothermal molecular assays, alongside optimization for semen analysis, which may alleviate barriers to diagnosis and present opportunities for integration with other sexual and reproductive health screening. These areas of future investigation underpin the development of a suitable diagnostic pipeline, as the continued neglect of MGS and its underdiagnosis presents a threat to the goal of elimination of schistosomiasis as a public health problem

    Utilizing the ultrasensitive Schistosoma up-converting phosphor lateral flow circulating anodic antigen (UCP-LF CAA) assay for sample pooling-strategies

    No full text
    Abstract Background Methodological applications of the high sensitivity genus-specific Schistosoma CAA strip test, allowing detection of single worm active infections (ultimate sensitivity), are discussed for efficient utilization in sample pooling strategies. Besides relevant cost reduction, pooling of samples rather than individual testing can provide valuable data for large scale mapping, surveillance, and monitoring. Method The laboratory-based CAA strip test utilizes luminescent quantitative up-converting phosphor (UCP) reporter particles and a rapid user-friendly lateral flow (LF) assay format. The test includes a sample preparation step that permits virtually unlimited sample concentration with urine, reaching ultimate sensitivity (single worm detection) at 100% specificity. This facilitates testing large urine pools from many individuals with minimal loss of sensitivity and specificity. The test determines the average CAA level of the individuals in the pool thus indicating overall worm burden and prevalence. When requiring test results at the individual level, smaller pools need to be analysed with the pool-size based on expected prevalence or when unknown, on the average CAA level of a larger group; CAA negative pools do not require individual test results and thus reduce the number of tests. Results Straightforward pooling strategies indicate that at sub-population level the CAA strip test is an efficient assay for general mapping, identification of hotspots, determination of stratified infection levels, and accurate monitoring of mass drug administrations (MDA). At the individual level, the number of tests can be reduced i.e. in low endemic settings as the pool size can be increased as opposed to prevalence decrease. Conclusions At the sub-population level, average CAA concentrations determined in urine pools can be an appropriate measure indicating worm burden. Pooling strategies allowing this type of large scale testing are feasible with the various CAA strip test formats and do not affect sensitivity and specificity. It allows cost efficient stratified testing and monitoring of worm burden at the sub-population level, ideally for large-scale surveillance generating hard data for performance of MDA programs and strategic planning when moving towards transmission-stop and elimination

    Refining Diagnosis of Schistosoma haematobium Infections: Antigen and Antibody Detection in Urine

    No full text
    Background: Traditional microscopic examination of urine or stool for schistosome eggs lacks sensitivity compared to measurement of schistosome worm-derived circulating antigens in serum or urine. The ease and non-invasiveness of urine collection makes urine an ideal sample for schistosome antigen detection. In this study several user-friendly, lateral-flow (LF) based urine assays were evaluated against a composite reference that defined infection as detection of either eggs in urine or anodic antigen in serum.Method: In a Tanzanian population with a S. haematobium prevalence of 40–50% (S. mansoni prevalence <2%), clinical samples from 44 women aged 18 to 35 years were analyzed for Schistosoma infection. Urine and stool samples were examined microscopically for eggs, and serum samples were analyzed for the presence of the anodic antigen. Urines were further subjected to a set of LF assays detecting (circulating) anodic (CAA) and cathodic antigen (CCA) as well as antibodies against soluble egg antigens (SEA) and crude cercarial antigen preparation (SCAP).Results: The urine LF anodic antigen assay utilizing luminescent upconverting reporter particles (UCP) confirmed its increased sensitivity when performed with larger sample volume. Qualitatively, the anodic antigen assay performed on 250 μL urine matched the performance of the standard anodic antigen assay performed on 20 μL serum. However, the ratio of anodic antigen levels in urine vs. serum of individual patients varied with absolute levels always higher in serum. The 10 μL urine UCP-LF cathodic antigen assay correlated with the commercially available urine POC-CCA (40 μL) test, while conferring better sensitivity with a quantitative result. Urinary antibodies against SEA and SCAP overlap and correlate with the presence of urinary egg and serum anodic antigen levels.Conclusions: The UCP-LF anodic antigen assay using 250 μL of urine is an expedient user-friendly assay and a suitable non-invasive alternative to serum-based antigen testing and urinary egg detection. Individual biological differences in the clearance process of the circulating antigens are thought to explain the observed high variation in the type and level of antigen (anodic or cathodic) measured in urine or serum. Simultaneous detection of anodic and cathodic antigen may be considered to further increase accuracy

    Impact of schistosome infection on long-term HIV/AIDS outcomes.

    No full text
    BACKGROUND: Africa bears the burden of approximately 70% of global HIV infections and 90% of global schistosome infections. We sought to investigate the impact of schistosome infection at the time of HIV-1 seroconversion on the speed of HIV-1 disease progression, as measured by the outcome CD4+ T-cell (CD4) counts <350 cells/μL and/or death. We hypothesized that people who had been infected with Schistosoma spp. at the time they acquired HIV-1 infection would have impaired antiviral immune response, thus leading them to progress twice as fast to a CD4 count less than 350 cells/μL or death than would people who had been free of schistosomes at time of HIV-1 seroconversion. METHODS AND PRINCIPAL FINDINGS: We conducted a longitudinal study in Tanzania from 2006 to 2017 using stored blood spot samples, demographic surveillance and sero-survey data from the community, and a review of clinical charts. A competing risk analysis was performed to look at the difference in time to reaching CD4 counts < 350 cells/μL and/or death in HIV-1-infected people who were infected versus not infected with Schistosoma spp. at time of HIV-1 seroconversion. We found an 82% reduction in risk of reaching the outcome in seroconverters who had been infected with Schistosoma (subHazard Ratio = 0.18[0.068,0.50], p = 0.001) after adjusting for age, occupation, clinic attendance and time-dependent covariates. CONCLUSIONS: Our study demonstrates that people with schistosome infection at the time of HIV-seroconversion develop adverse HIV outcomes more slowly than those without. The findings are contrary to our original hypothesis. Our current longitudinal findings suggest complex interactions between HIV-1 and schistosome co-infections that may be modulated over time. We urge new immunological studies to investigate the long-term impact of schistosome infection on HIV-1 viral load and CD4 counts as well as related immunologic pathways

    Diagnosis of Schistosomiasis without a Microscope: Evaluating Circulating Antigen (CCA, CAA) and DNA Detection Methods on Banked Samples of a Community-Based Survey from DR Congo

    No full text
    Detection of Schistosoma eggs in stool or urine is known for its low sensitivity in diagnosing light infections. Alternative diagnostics with better sensitivity while remaining highly specific, such as real-time PCR and circulating antigen detection, are progressively used as complementary diagnostic procedures but have not yet replaced microscopy. This study evaluates these alternative methods for the detection of Schistosoma infections in the absence of microscopy. Schistosomiasis presence was determined retrospectively in 314 banked stool and urine samples, available from a previous survey on the prevalence of taeniasis in a community in the Democratic Republic of the Congo, using real-time PCR, the point-of-care circulating cathodic antigen (POC-CCA) test, as well as the up-converting particle lateral flow circulating anodic antigen (UCP-LF CAA) test. Schistosoma DNA was present in urine (3%) and stool (28%) samples, while CCA (28%) and CAA (69%) were detected in urine. Further analysis of the generated data indicated stool-based PCR and the POC-CCA test to be suitable diagnostics for screening of S. mansoni infections, even in the absence of microscopy. A substantial proportion (60%) of the 215 CAA-positive cases showed low antigen concentrations, suggesting that even PCR and POC-CCA underestimated the &ldquo;true&rdquo; number of schistosome positives

    Comparison of novel and standard diagnostic tools for the detection of Schistosoma mekongi infection in Lao People's Democratic Republic and Cambodia

    No full text
    Given the restricted distribution of Schistosoma mekongi in one province in Lao People's Democratic Republic (Lao PDR) and two provinces in Cambodia, together with progress of the national control programmes aimed at reducing morbidity and infection prevalence, the elimination of schistosomiasis mekongi seems feasible. However, sensitive diagnostic tools will be required to determine whether elimination has been achieved. We compared several standard and novel diagnostic tools in S. mekongi-endemic areas.; The prevalence and infection intensity of S. mekongi were evaluated in 377 study participants from four villages in the endemic areas in Lao PDR and Cambodia using Kato-Katz stool examination, antibody detection based on an enzyme-linked immunosorbent assay (ELISA) and schistosome circulating antigen detection by lateral-flow tests. Two highly sensitive test systems for the detection of cathodic and anodic circulating antigens (CCA, CAA) in urine and serum were utilized.; Stool microscopy revealed an overall prevalence of S. mekongi of 6.4% (one case in Cambodia and 23 cases in Lao PDR), while that of Opisthorchis viverrini, hookworm, Trichuris trichiura, Ascaris lumbricoides and Taenia spp. were 50.4%, 28.1%, 3.5%, 0.3% and 1.9%, respectively. In the urine samples, the tests for CCA and CAA detected S. mekongi infections in 21.0% and 38.7% of the study participants, respectively. In the serum samples, the CAA assay revealed a prevalence of 32.4%, while a combination of the CAA assay in serum and in urine revealed a prevalence of 43.2%. There was a difference between the two study locations with a higher prevalence reached in the samples from Lao PDR.; The CCA, CAA and ELISA results showed substantially higher prevalence estimates for S. mekongi compared to Kato-Katz thick smears. Active schistosomiasis mekongi in Lao PDR and Cambodia might thus have been considerably underestimated previously. Hence, sustained control efforts are still needed to break transmission of S. mekongi. The pivotal role of highly sensitive diagnostic assays in areas targeting elimination cannot be overemphasised
    corecore