79 research outputs found
Standardized loads acting in knee implants
The loads acting in knee joints must be known for improving joint replacement, surgical procedures, physiotherapy, biomechanical computer simulations, and to advise patients with osteoarthritis or fractures about what activities to avoid. Such data would also allow verification of test standards for knee implants. This work analyzes data from 8 subjects with instrumented knee implants, which allowed measuring the contact forces and moments acting in the joint. The implants were powered inductively and the loads transmitted at radio frequency. The time courses of forces and moments during walking, stair climbing, and 6 more activities were averaged for subjects with I) average body weight and average load levels and II) high body weight and high load levels. During all investigated activities except jogging, the high force levels reached 3,372–4,218N. During slow jogging, they were up to 5,165N. The peak torque around the implant stem during walking was 10.5 Nm, which was higher than during all other activities including jogging. The transverse forces and the moments varied greatly between the subjects, especially during non-cyclic activities. The high load levels measured were mostly above those defined in the wear test ISO 14243. The loads defined in the ISO test standard should be adapted to the levels reported here. The new data will allow realistic investigations and improvements of joint replacement, surgical procedures for tendon repair, treatment of fractures, and others. Computer models of the load conditions in the lower extremities will become more realistic if the new data is used as a gold standard. However, due to the extreme individual variations of some load components, even the reported average load profiles can most likely not explain every failure of an implant or a surgical procedure
Loads on an Internal Spinal Fixation Device During Physical Therapy
Abstract
Background and Purpose. Modified internal spinal fixation devices allow the measurement of the forces and moments acting on the implants. The aim of this study was to measure the loads on internal fixation devices for selected body positions and movements during physical therapy. Subjects and Methods. Loads on an internal spinal fixation device were measured in 10 patients with degenerative instability or compression fractures using a telemeterized implant. Results. Relatively low implant loads were found in the recumbent body positions. Most exercises performed in a lying position caused implant loads less than that measured for standing and are therefore not likely to increase the risk of screw breakage. Fixation device loads were lower for sitting relaxed than for standing. The highest implant loads (128% of the value for standing) were measured during walking. Standing up, sitting down, and lateral bending and axial rotation of the upper body while standing led to fixation device loads between 111% and 120% related to the value for standing. Even higher fixation device loads were measured for ventral flexion and extension of the upper body while standing. Kneeling on hands and knees, and flexing and extending the back in this position, caused implant loads that were lower than for standing. Discussion and Conclusion. Standing up, sitting down, and lateral bending and axial rotation of the upper body while standing may slightly increase the risk of pedicle screw breakage, whereas ventral flexion and extension of the upper body while standing may increase this risk considerably if the region bridged by the implant is distracted (the distance between upper and lower screws was increased) during surgery. However, walking is the exercise that plays the major role concerning pedicle screw breakage because it causes the highest bending moments of all exercises studied and it loads the fixation devices most frequently.</jats:p
Spinal loads during cycling on an ergometer.
Cycling on an ergometer is an effective exercise for improving fitness. However, people with back problems or previous spinal surgery are often not aware of whether cycling could be harmful for them. To date, little information exists about spinal loads during cycling. A telemeterized vertebral body replacement allows in vivo measurement of implant loads during the activities of daily living. Five patients with a severe compression fracture of a lumbar vertebral body received these implants. During one measurement session, four of the participants exercised on a bicycle ergometer at various power levels. As the power level increased, the maximum resultant force and the difference between the maximum and minimum force (force range) during each pedal revolution increased. The average maximum-force increases between the two power levels 25 and 85 W were 73, 84, 225 and 75 N for the four patients. The corresponding increases in the force range during a pedal revolution were 84, 98, 166 and 101 N. There were large variations in the measured forces between the patients and also within the same patient, especially for high power levels. In two patients, the maximum forces during high-power cycling were higher than the forces during walking measured on the same day. Therefore, the authors conclude that patients with back problems should not cycle at high power levels shortly after surgery as a precaution
- …