87,172 research outputs found

    Classification of hypervascularized lesions in CE MR imaging of the breast

    No full text
    The purpose of this paper is to define and evaluate a classification category for contrast-enhanced (CE) MR imaging of the breast based on the BI-RADS mammographic categories of the American College of Radiology. Using five evaluation criteria for MR findings (initial signal increase, postinitial signal behavior, shape, border, and contrast material distribution within enhancing tumors) 522 patients (1031 breasts) were analyzed. Scores were given from 0 to 8 points and classified into five categories (group 1: 0 points, negative; group 11: 1-2 points, benign; group 111: 3 points, probably benign; group IV: 4-5 points, suspicious abnormality; group V: 6-8 points, highly suspicious for malignancy) to 265 focal hypervascularized breast lesions in 244 breasts (patient group A). These findings were correlated with histology or follow-up. Additionally, this classification was correlated to the contrast medium uptake within the parenchyma of the remaining 787 breasts without any focal lesion (patient group 13). Two hundred sixty-five hypervascularized lesions in 238 patients (244 breasts, patient group A) were classified into group 1: 0%; group 11: 27.3%; group 111: 22.3%; group IV: 18.6%; and group V: 31.8%. Histology revealed 115 benign and 134 malignant tumors in these groups. Sixteen benign lesions were controlled by follow-up. Sensitivity for the detection of malignancy using the presented multifactorial MRM classification was 92%, and specificity was 92%. Excluding cases of ductal carcinoma in situ specificity increased to 95%. Seven hundred eighty-seven breasts without any focal hypervascularized lesion (patient group 13) were classified into groups I or II. Follow-up (n=771) or histology (n=14) confirmed the diagnosis in 785 of these breasts. Histopathology revealed, however, malignant tumors in the remaining two cases. The classification of lesions based on a multifactorial analysis is very helpful in the interpretation of CE MRI of the breast. The evaluation of all diagnostic imaging modalities, however, is essential in determining the correct diagnosis and/or in deciding on the appropriate therapeutic procedure

    Indications for percutaneous stereotactic vacuum core biopsy of the breast

    No full text
    As a consequence of technical improvements and an increased number of investigations in asymptomatic patients, more and more suspicious lesions are being detected in mammography. These lesions can be evaluated using different biopsy techniques. In comparison to open biopsy, stereotactic methods require less costs and time, and reduce morbidity. The introduction of the vacuum core biopsy method allowed the excision of suspicious areas through a single needle insertion. In the current literature, however, the indications for vacuum core biopsy are being discussed controversely. This article includes an introduction of this specific technique, a presentation of the BI-RADS(TM) (Breast Imaging Reporting and Data System) categories and an overview of the literature of the indications for use of the vacuum system. The "pros and cons" of vacuum core biopsy will be discussed in comparison with the alternative biopsy methods

    The contribution of different postprocessing methods for multislice spiral CT in acute pulmonary embolism

    No full text
    Purpose: To investigate the value of different postprocessing algorithms for multislice spiral CT (MSCT) in diagnosing acute pulmonary embolism. Materials and Methods: Forty-eight patients with suspected pulmonary embolism prospectively underwent MSCT using an 8-slice spiral CT. Using a confidence level on a three-point scale, three radiologists reviewed 2-mm and 5-mm axial slices, 5-mm and 10-mm axial maximum intensity projections (MIP) and 2-mm coronal slices as well as interactively generated multiplanar reformatted images. A subsequent consensus reading of the primary 1.25-mm axial slices served as gold standard. ROC analysis was applied to the various vascular sections. Results: The ROC analysis revealed a higher diagnostic accuracy of the 2-mm axial sections as compared to the 5-mm axial slices (Az = [0.988;0.976] vs. Az = [0.988-,0.802]). Coronal and multiplanar reformations also showed excellent diagnostic accuracy (Az = [0.972;0.949] and Az = [0.997;0.951], respectively) and were significantly superior to the 5-mm axial slices through the segmental and subsegmental arteries (p=0.05). MIP showed the weakest diagnostic accuracy (Az = [0.967;0.802] for 5-mm MIP; Az = [0.879;0.781] for 10-mm MIP). Conclusion: Thin axial slices as well as coronal and multiplanar reformations are superior to thick axial slices in the diagnosis of acute pulmonary embolism. MIP is not suited for accurate diagnosis of pulmonary embolic disease

    Computer-aided detection in direct digital full-field mammography: initial results

    No full text
    For the first time, fullfield digital mammography (FFDM) allows computer-aided detection (CAD) analysis of directly acquired digital image data. The purpose of this study was to evaluate a CAD system in patients with histologically correlated breast cancer depicted with FFDM. Sixty-three cases of histologically proven breast cancer detected with FFDM (Senographe 2000D, GE Medical Systems, Buc, France) were analyzed using a CAD system (Image Checker V2.3, R2 Technology, Los Altos, Calif.). Fourteen of these malignancies were characterized as microcalcifications, 37 as masses, and 12 as both. The mammographic findings were categorized as BI-RADS 3 (n=5), BI-RADS 4 (n=17) and BI-RADS 5 (n=40). The sensitivity for malignant lesions and the rate of false-positive marks per image were calculated. The sensitivity and its 95% confidence interval (CI) were estimated. The sensitivity of the CAD R2 system in breast cancer seen on FFDM was 89% for microcalcifications [CI95%=(70%; 98%)] and 81% for masses [CI95%=(67%; 91%)]. As expected, the detection rate was higher in lesions categorized as BI-RADS 5 (37 of 40) compared with lesions categorized as BI-RADS 4 (11 of 17). In the group categorized as BI-RADS 3 the detection rate was 4 of 5 lesions; however, this group was very small. The rate of false-positive marks was 0.35 microcalcification marks/image and 0.26 mass marks/image. The overall rate of false-positive marks was 0.61 per image. CAD based on FFDM provides an optimized work flow. Results are equivalent to the results reported for CAD analysis of secondarily digitized image data. Sensitivity for microcalcifications is acceptable and for masses is low. The number of false-positive marks per image should be reduced

    Artifacts of vascular stents in 3D MR angiography: experimental studies.

    No full text
    Purpose: The purpose of this phantom study was to evaluate the visualization of vascular stents by using contrast-enhanced (CE) 3D MR angiography (MRA). Methods: The measurements were performed on a Magnetom Vision operating at 1.5 T with 25 mT/m gradients by using a head coil; a 3D FISP sequence (TR/TE/FA 4.6 ms/1.8 ms/30 degrees) was used. A phantom was designed with a length of 20 cm and consisted of a plastic cylinder filled with hydrogel. Tubes were used to install 7 different stents (Strecker, Boston Scientific; Cragg, Mintec; Walt, Schneider; Memotherm, Angiomed; St-Come, Trigon-MTS; Sinus, Optimed: Palmaz, Johnson & Johnson) with different metal components. The tubes were perfused with a solution of water and Gd-DTPA. Four radiologists evaluated the image quality. The measurements of the endoluminal stent diameters were compared with the findings obtained by digital subtraction angiography. The signal intensities were measured before (inflow), within (stent) and after (outflow) the different stent types. Results: The endoluminal diameter of the Cragg stent and the strecker graft were easily detectable. The signal loss within the lumen of the Wall stent was approx. 10% in relation to the inflow and outflow measurements. The result was an only slightly reduced image quality. The other grafts (St-Come, Sinus, Palmaz, Memotherm) showed significant signal losses ranging From 65% to 96%. A correct diagnosis was not possible within these graft lumina. Conclusion: Contrast-enhanced MR angiography can be used to evaluate vascular stents. A prerequisite is the application of particular commercially available grafts

    Value of F-18FDG hybrid camera PET and MRI in early takayasu aortitis

    No full text
    Takayasu aortitis (TA) is a chronic inflammatory and fibrotic vasculitis of large- and medium-sized arteries. Early stages of the disease show a panarteritis and inflammatory wall thickening of the aorta and its branches, whereas advanced (fibrotic) stages comprise stenosis, aneurismatic transformation and occlusion. Magnetic resonance imaging visualises early-stage disease with high accuracy and is considered to be the method of choice in the diagnosis of TA. The aim of this article is the detailed comparison of FDG-PET performed with a hybrid camera and MR imaging in five patients with early TA. Five patients (median age 60 years) were enrolled during an ongoing prospective study on [18F]2'-deoxy-2-fluoro-D-glucose (FDG) hybrid camera PET in patients with fever of unknown origin (FUO). These patients underwent MR imaging after establishing the diagnosis of TA. Abnormal FDG uptake in the wall of the aorta was noted in all patients. The bracheocephalic artery and the common carotid arteries were visualized in 3 cases. Increased uptake of the subclavian artery was found in 3 patients and in 4 patients pathological uptake was noted in the ilio-femoral vessels. Of 34 vascular regions studied, 26 (76%) showed elevated FDG uptake. On transversal MR images vessel wall thickening and contrast enhancement of the thoracic aorta was found in 4 patients (ascending aorta/ aortic arch: n=2; descending aorta: n=3; abdominal aorta: n=1). Additionally, vessel wall pathologies of the subclavian and the common carotid arteries could be shown in 1 patient and in another patient in the ilio-femoral arteries. No abnormalities were found using contrast-enhanced MR angiography. Of 28 vascular regions studied, 9 (32%) showed vasculitis on MRI. The FDG-PET is a suitable whole-body screening method in the primary diagnosis of early TA, especially in those cases with early disease that present with uncharacteristic symptoms such as FUO. Both MRI and MRA remain indispensable in the exact determination of the pathomorphological changes and in the documentation of complications such as stenosis, aneurismatic transformation and occlusion

    Variations on the Author

    No full text
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Semi-automatic classification of skeletal morphology in genetically altered mice using flat-panel volume computed tomography.

    No full text
    Rapid progress in exploring the human and mouse genome has resulted in the generation of a multitude of mouse models to study gene functions in their biological context. However, effective screening methods that allow rapid noninvasive phenotyping of transgenic and knockout mice are still lacking. To identify murine models with bone alterations in vivo, we used flat-panel volume computed tomography (fpVCT) for high-resolution 3-D imaging and developed an algorithm with a computational intelligence system. First, we tested the accuracy and reliability of this approach by imaging discoidin domain receptor 2- (DDR2-) deficient mice, which display distinct skull abnormalities as shown by comparative landmark-based analysis. High-contrast fpVCT data of the skull with 200 microm isotropic resolution and 8-s scan time allowed segmentation and computation of significant shape features as well as visualization of morphological differences. The application of a trained artificial neuronal network to these datasets permitted a semi-automatic and highly accurate phenotype classification of DDR2-deficient compared to C57BL/6 wild-type mice. Even heterozygous DDR2 mice with only subtle phenotypic alterations were correctly determined by fpVCT imaging and identified as a new class. In addition, we successfully applied the algorithm to classify knockout mice lacking the DDR1 gene with no apparent skull deformities. Thus, this new method seems to be a potential tool to identify novel mouse phenotypes with skull changes from transgenic and knockout mice on the basis of random mutagenesis as well as from genetic models. However for this purpose, new neuronal networks have to be created and trained. In summary, the combination of fpVCT images with artificial neuronal networks provides a reliable, novel method for rapid, cost-effective, and noninvasive primary screening tool to detect skeletal phenotypes in mice

    [Newspaper Clipping: Author Claims Evidence of Second JFK Assassin #1]

    No full text
    Newspaper article titled "Author Claims Evidence of Second JFK Assassin." The article states that author Richard J. Whalen concluded "that there is circumstantial evidence to support the theory of a second assassin in the shooting of President John F. Kennedy.
    corecore