2,239 research outputs found

    Replication Data for: Reporting of academic degrees in high-impact medical journals

    No full text
    We identified the hundred highest impact medical journals based on impact factor reported in the Journal Citation Reports published in 2018. Characteristics of each journal in regard to specialty, impact factor, primary journal focus, continent, and open access policy were obtained. Data were collected on the presence of academic degrees following author names in the title page by assessment of multiple original research articles from each journal. Approximately ten articles published in July 2018 and August 2019 were assessed for each journal. If there was any discrepancy between the print and the online version, the print version was use. There were no discrepancies within journals for the two time periods

    Replication Data for: Reporting of academic degrees in high-impact medical journals

    No full text
    We identified the hundred highest impact medical journals based on impact factor reported in the Journal Citation Reports published in 2018. Characteristics of each journal in regard to specialty, impact factor, primary journal focus, continent, and open access policy were obtained. Data were collected on the presence of academic degrees following author names in the title page by assessment of multiple original research articles from each journal. Approximately ten articles published in July 2018 and August 2019 were assessed for each journal. If there was any discrepancy between the print and the online version, the print version was use. There were no discrepancies within journals for the two time periods

    Adaptive Controller For D-Statcom in the Stationary Reference Frame to Compensate for Reactive and Harmonic Distortion Under Unbalanced Conditions

    No full text
    A controller (130) for compensating reactive power and selected current load harmonics in an unbalanced multi-phase power distribution system. Control current is injected from a multi-phase voltage source inverter (118) into the multi-phase power distribution system as a function of the voltage and current provided by the source inverter 118. The injected current is operative to balance the load seen by the power distribution system including non-linear/distorted and unbalanced loads in each phase. The controller includes an inner loop control processor (216), an outer loop control processor, and an adaptation processor. The adaptation processor (238) is operative to estimate a selected set of predetermined harmonic components in the periodic disturbance which is a function of the unknown system parameters, the source current, the source voltage, and their time derivatives in stationary coordinates

    An Adaptive Controller in the stationary reference frame for D-Statcom in unbalanced operation

    No full text
    This paper presents a passivity-based controller for a Distribution Static synchronous Compensator (D-Statcom) aimed at compensating reactive power and unbalanced harmonics in the general case of distorted and unbalanced source voltages and load currents. The proposed approach is based on the measurements of line currents, and ensures precise compensation for selected harmonics. Moreover, in order to compensate for the unavoidable uncertainty in certain system parameters, adaptation is added to the passivity-based controller. One of the major advantages of the proposed solution compared to conventional alternatives is that we are able to perform precise tracking (including higher order harmonics) even in the presence of a relatively low switching frequency, i.e., in the presence of an inverter with limited bandwidth. Simulation and experimental results are provided to illustrate the merits of our solution
    corecore