1,723,531 research outputs found
Mcnpx calculations of specific absorbed fractions in some organs of the human body due to application of 133xe, 99mtc and 81mkr radionuclides
Monte Carlo simulations were performed to evaluate treatment doses with wide spread used radionuclides 133Xe, 99mTc and 81mKr. These different radionuclides are used in perfusion or ventilation examinations in nuclear medicine and as indicators for cardiovascular and pulmonary diseases. The objective of this work was to estimate the specific absorbed fractions in surrounding organs and tissues, when these radionuclides are incorporated in the lungs. For this purpose a voxel thorax model has been developed and compared with the ORNL phantom. All calculations and simulations were performed by means of the MCNP5/X code. © The Author 2017. Published by Oxford University Press. All rights reserved
Fluence to Hp (3) conversion coefficients for neutrons from thermalto 15 mev
The recent statement on tissue reactions issued by the International Commission on Radiological Protection in April 2011 recommends a very significant reduction in the equivalent dose annual limit for the eye lens from 150 to 20 mSv y-1; this has stimulated a lot of interest in eye lens dosimetry in the radiation protection community. Until now no conversion coefficients were available for the operational quantity Hp(3) for neutrons. The scope of the present work was to extend previous evaluations of Hz.ast;(10) and Hp(10) performed at the PTB in 1995 to provide also Hp(3) data for neutrons. The present work is also intended to complete the studies carried out on photons during the last 4 y within the European Union-funded ORAMED (optimisation of radiation protection for medical staff) project. © The Author 2013. Published by Oxford University Press. All rights reserved
The CP Nature of the Top-Yukawa Coupling: among other measurements in the gluon gluon fusion production channel
Contains fulltext :
214421.pdf (Publisher’s version ) (Open Access)Radboud University, 20 mei 2019Promotor : Groot, N. de Co-promotor : Ferrari, P.190 p
Eye lens monitoring for interventional radiology personnel: Dosemeters, calibration and practical aspects of H p(3) monitoring. A 2015 review
A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p(3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended. © 2015 IOP Publishing Ltd
Monte Carlo study of the scattered radiation field near the eyes of the operator in interventional procedures
Interventional radiology and cardiology guarantee high benefits for patients, but are known to be associated with a high level of radiation exposure of medical staff. The recently suggested decrease of the annual dose limit for the eye lens, from 150 to 20 mSv, caused a need for a reconsideration of practices ensuring sufficient protection for the lens of the eyes of medical staff. In such context the study of the scattered radiation around the operator's head could help in finding the best solutions to be adopted for the ceiling-suspended shield and lead glasses in the most common situations in interventional practices. MCNPX Monte Carlo code was employed with anthropomorphic mathematical phantoms to simulate interventional practice projections. For each projection the effect of changing selected parameters on the evaluated scattered radiation towards the operator's head has been calculated. The variety of modelled situations provides plentiful material regarding the spatial distribution of the scattered radiation, useful to improve eye lens radiation protection, such as the following: (a) Glasses, which provide shielding from both lateral and bottom-up scattered radiation, can reduce by ten times the exposure to the most exposed eyes; (b) The ceiling-suspended shield offers valuable protection, but such effectiveness can diminish by 90% if the shielding is not correctly positioned; (c) The transition from femoral to radial access usually intensifies the scattered radiation toward the operator head (a factor of 1.5 for AP projection), but for RAO projections, a reduction of the order by two to three times, in the case of radial access, can be seen, due to the protection provided by the image receptor. The detailed fluence outcomes show that there is a preferential direction of the impinging scattered radiation that should be considered when radiation protection options are evaluated or when a dedicated eye lens dosemeter is used for monitoring. © 2016 IOP Publishing Ltd
- …
