4,429 research outputs found

    Mallet finger: a single-blind randomised controlled trial of three different splints: data

    No full text
    The goal of the research project was to find the most appropriate way to manage mallet finger injuries and which of three types of splint intervention provided the best results. Data was collected at outpatient hand therapy clinics in two Victorian public hospitals and one private clinic by practitioners Emmaline Fooks, Kylie Chandler, Melanie McCulloch, Lisa Licciardi, Ben Cunningham, Ellen Jacobs, Alison Hardman, Sharon Goldby and Zoe Milner. Elizabeth (Lisa) O'Brien from the Department of Occupational Therapy and Michael Bailey from the Department of Epidemiology from Monash University co-ordinated the assessment of the data. Data on mallet finger injury was collected from patients suffering the condition and de-identified for assessment. Data collected compared prefabricated stack, dorsal padded aluminium splint and custom thermoplastic thimble splint techniques in patients with acute type 1a or b mallet finger. The three types of splint were worn for 8 weeks continuously, with a 4 week graduated withdrawal and exercise program then assessed for the most tolerated splint and the best outcome for the patient. Data measured primary outcome (extensor lag) at 12 and 20 weeks.64 survey forms (print); 1 excel file (xml); 1 SAS file(sas ); total size of data set 2G

    Disruption of the developmental programme of Trypanosoma brucei by genetic ablation of TbZFP1, a differentiation-enriched CCCH protein

    No full text
    The regulation of differentiation is particularly important in microbial eukaryotes that inhabit multiple environments. The parasite Trypanosoma brucei is an extreme example of this, requiring exquisite gene regulation during transmission from mammals to the tsetse fly vector. Unusually, trypanosomes rely almost exclusively on post-transcriptional mechanisms for regulated gene expression. Hence, RNA binding proteins are potentially of great significance in controlling stage-regulated processes. We have previously identified TbZFP1 as a trypanosome molecule transiently enriched during differentiation to tsetse midgut procyclic forms. This small protein (101 amino acids) contains the unusual CCCH zinc finger, an RNA binding motif. Here, we show that genetic ablation of TbZFP1 compromises repositioning of the mitochondrial genome, a specific event in the strictly regulated differentiation programme. Despite this, other events that occur both before and after this remain intact. Significantly, this phenotype correlates with the TbZFP1 expression profile during differentiation. This is the first genetic disruption of a developmental regulator in T. brucei. It demonstrates that programmed events in parasite development can be uncoupled at the molecular level. It also further supports the importance of CCCH proteins in key aspects of trypanosome cell function

    Tension strength capacity of finger joined beech lamellas

    No full text
    Beech wood has high mechanical properties, therefore the production of high quality beech glulam beams is one of our main objectives. Finger joints with standard geometries and adhesives used for joining coniferous wood are not sufficient in terms of strength when gluing beech wood. A hybrid glulam beam was produced and tested in a standard four point bending test. The beam was produced from finger joined beech lamellas on the outer sides and finger joined spruce lamellas in the middle. The results from the bending test showed a lack of tensile strength of the finger joints of beech lamellas on the bottom middle part of the beam, where the rupture occurred. We prepared a numerical model of finger joined beech lamellas and simulations of tension tests, parallel to the lamella. We performed parametric studies with multiple variables referring to geometrical properties of finger joints and two different types of applied adhesives. The results showed a high influence of the finger joint geometrical parameters. Experimental tests on the tension strength of the finger joints were performed. Two finger joint lengths were tested, 10 and 20 millimetres. The results showed a clear influence of the finger joint geometry where highest strengths were obtained with longer and thinner fingers

    Do rules control power? GATT articles and arrangements in the Uruguay Round

    No full text
    Many complain and offer evidence that in recent years the GATT system has become more power-oriented, less stable, and less equitable. A concern to reverse this drift was one of the motives that brought the international community to agree to undertake the Uruguay Round. Rules control power, assumed the signers of the Punte del Este declaration, therefore elaborating and extending GATT rules would move the international community toward a fairer, more stable international trading system. Finger and Dhar contend that the opposite is true. Particularly in the 1980s, the elaboration and application of GATT rules has been an exercise in the application of economic and political power, not in its control. GATT rules, in theory, are there to limit national trade restrictions. Finger and Dhar contend that in fact things work the other way around: national practice comes first, and determines what the GATT rules mean. GATT's rules do not put limits on national practices, but provide international santion for these practices. Such rules are not part of the thereforelution but are part of the problem. Theirs is a situation-specific argument, say Finger and Dhar, not a generic one. Their target is not"rules", nor is it"GATT". Rather, it is the GATT rules.Rules of Origin,TF054105-DONOR FUNDED OPERATION ADMINISTRATION FEE INCOME AND EXPENSE ACCOUNT,Common Carriers Industry,Transport and Trade Logistics,Trade Policy

    Comparing the Active, Functional, and Passive Range of Motion of Finger Joints Using Dynamic Measurement

    No full text
    Studies on finger kinematics, especially the range of motion (RoM) measurements, are essential to understand the use of finger joints and the pathology of related disease. Limited literatures compared the active RoM (A-RoM) of finger joints with either their functional RoM (F-RoM) or passive RoM (p-RoM) using different measuring protocols and tools. This study aims to provide an overall comparison including all three types of RoMs. We measured A-RoM, F-RoM, and P-RoM, using a dynamic measurement system. Our goal is to investigate the relationships among the three RoMs by comparing their extreme rotation angles. The results suggested that P-RoM was the largest motion range, and F-RoM can exceed their A-RoM. The F-RoM of distal-interphalangeal joints may rotated 8–20° more than their A-RoM, mainly during precise and power manipulations. Besides to A-RoM, knowledge of F-RoM and P-RoM are also important for a comprehensive understanding for clinical practice, and thus, to support the optimization and evaluation of treatment devices for finger joint, such as implant replacement.Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Human-Centered DesignApplied Ergonomics and Desig

    CamPressID: Optimizing Camera Configuration and Finger Pressure for Biometric Authentication

    No full text
    To protect sensitive information on smartphones, state-of-the-art (SoA) studies exploit the built-in camera to capture PPG signals from fingertips as a hard-to-forge biometric. However, those studies do not provide a comprehensive analysis to optimize the camera parameters and finger pressure, leading to distorted and unstable PPG signals that degrade the authentication performance. To overcome these limitations, we propose the CamPressID framework. First, we analyze various camera parameters and optimize their configuration to obtain PPG signals with a high signal-to-noise ratio. Second, we investigate different finger pressures to identify the best pressure for every subject, in order to avoid signal distortion. To evaluate the performance of CamPressID, we collect a diverse dataset with 58 subjects. Our evaluation results show that CamPressID can improve the average balanced accuracy (BAC) by 10%. Moreover, the BAC reaches 90%, which is similar to the accuracy reported in the SoA using a dedicated PPG sensor for authentication.Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Embedded SystemsWeb Information System

    SoftGlove: Finger Vibrotactile Feedback

    No full text
    In this report the finger vibrotactile subsystem of the SoftGlove wearable haptic feedback glove is discussed. This system is an upgrade over the vibrotactile feedback that the current SenseGlove haptic feedback glove provides. The designed system consists of a linear resonant actuator (LRA) on each finger, which is controlled by a dedicated LRA driver over I2C. To overcome addressing limitations of the drivers, an I2C switch is used to be able to communicate with each driver individually. The system is characterized both in terms of latency and vibration strength. The peak-to-peak vibration strength is measured to be 1.44 G and a 10 % to 90 % rise and fall time of 44 ms from rest to the maximum vibration strength. Furthermore, the system is integrated with the other subsystems of the SoftGlove on a PCB.SoftgloveElectrical Engineerin

    Impact of zinc and iron agronomic biofortification on grain mineral concentration of finger millet varieties as affected by location and slope

    No full text
    Background: Food crop micronutrient concentrations can be enhanced through agronomic biofortification, with the potential to reduce micronutrient deficiencies among rural population if they have access to fertilizers. Here we reported the impact of agronomic biofortification on finger millet grain zinc (Zn) and iron (Fe) concentration. Methods: A field experiment was conducted in farmers’ fields in Ethiopia in two locations; over two seasons in one district (2019 and 2020), and over a single season (2019) in a second district. The experimental design had 15 treatment combinations comprising 3 finger millet varieties and 5 soil-applied fertilizer treatments: (T1) 20 kg ha−1 FeSO4 + 25 kg ha−1 ZnSO4 + NPKS; (T2) 25 kg ha−1 ZnSO4 + NPKS; (T3) NPKS; (T4) 30% NPKS; (T5) 20 kg ha−1 FeSO4 + NPKS. The treatments were studied at two slope positions (foot and hill), replicated four times in a randomized complete block design. Results: Grain Zn concentration increased by 20% in response to Fe and Zn and by 18.9% due to Zn addition. Similarly, grain Fe concentration increased by 21.4% in T1 and 17.8% in T5 (Fe). Zinc fertilizer application (p < 0.001), finger millet variety (p < 0.001), and an interaction of Fe and Zn had significant effect on grain Zn concentration. Iron fertilizer (p < 0.001) and interactive effect of Fe fertilizer and finger millet variety (p < 0.01) had significant effects on grain Fe concentration. Location but not slope position was a source of variation for both grain Zn and Fe concentrations. Conclusion: Soil application of Zn and Fe could be a viable strategy to enhance grain Zn and Fe concentration to finger millet grain. If increased grain Zn and Fe is bioavailable, it could help to combat micronutrient deficiencies

    Exploring solutions for finger tremor patients: Designing finger tremor suppression through passive wearable

    No full text
    This report presents an explorative study in finding solutions for finger tremor patients diagnosed with Essential Tremor (ET). Tremors restrict patients from performing delicate movements, creating difficulty in daily activities, such as drinking, writing, cooking or eating. Besides the challenges in performing tasks, social anxiety often occurs and negatively influences social life.Currently, solutions for people with tremors are limited. STIL recognized this need and designed an orthosis for people with wrist tremors. The solution from STIL is an orthosis called the BEAM. The BEAM mechanically suppresses the wrist flexion extension and forearm pronation-supination tremors. Evaluation of the current BEAM concluded that wrist tremors are successfully suppressed, but tremors situated mainly in the fingers need additional stabilization. This study aims to design a functional wearable that mechanically suppresses finger tremors.To better understand finger tremors, the project provides information on hand anatomy, the current market for finger wearables, and a video analysis of previous tests from STIL. The research found that there is limited knowledge about finger tremors and available wearables specifically designed for them. In user tests STIL saw many people with tremors also deal with a finger tremor, people can benefit from a finger wearable . In addition, the design scope research aimed to identify the specific needs and desires of people with finger tremors. The focus is on discovering a healthy and comfortable balance between freedom of movement and suppression of the fingers. The research conducted with three participant showed that the thumb, index, and middle fingers at the MCP (third joint from top of finger) and PIP (second joint from top of finger) joints need to be suppressed and that participants desire an inconspicuous and open design.The ideation phase exists out of multiple iterations. The basis of the ideation is a meeting with an expert in Emerging Materials, a morphological card, and brainstorming with the team of STIL. The basis concluded in four promising design directions, which could suppress the finger tremor: wires with springs, gel/air damping, elastic bands, and splints with different stiffnesses. Prototypes were built to research and test the four directions. Finally, the most interesting concepts are elastic bands and splints with different stiffness. The elastic bands give a counterforce to the fingers by pulling them backward. The silicone splints in a glove are made of silicone with spring steel which lies on the fingers. The working principle and ergonomics of the elastic bands and silicone splints have been validated in patient research. The results showed that the silicone splints were better in terms of performance and comfort, while the elastic bands were preferred in terms of design and adaptability. The final concept used the working principle of silicone splints. The final iteration focuses on appearance, ergonomics, usability, and connection to the BEAM.In conclusion, this report provides a foundation for STIL to further develop a wearable solution for people with finger tremors. The working principle of using silicone splints to suppress finger tremors is promising, but additional iterations are necessary.Integrated Product Design | Medisig

    Differences in the nutritional quality of improved finger millet genotypes in Ethiopia

    No full text
    Improved crop genotypes are constantly introduced. However, information on their nutritional quality is generally limited. The present study reports the proximate composition and the concentration and relative bioavailability of minerals of improved finger millets of different genotypes. Grains of finger millet genotypes (n = 15) grown in research station during 2019 and 2020 in Ethiopia, and replicated three times in a randomized complete block design, were analysed for proximate composition, mineral concentration (iron, zinc, calcium, selenium), and antinutritional factors (phytate, tannin and oxalate). Moreover, the antinutritional factors to mineral molar ratio method was used to estimate mineral bioavailability. The result shows a significant genotypic variation in protein, fat and fibre level, ranging from 10% to 14.6%, 1.0 to 3.8%, and 1.4 to 4.6%, respectively. Similarly, different finger millets genotypes had significantly different mineral concentrations ranging from 3762 ± 332 to 5893 ± 353mgkg−1 for Ca, 19.9 ± 1.6 to 26.2 ± 2.7mgkg−1 for Zn, 36.3 ± 4.6 to 52.9 ± 9.1mgkg−1 for Fe and 36.6 ± 11 to 60.9 ± 22µgkg−1 for Se. Phytate (308–360µgg−1), tannin (0.15–0.51mgg−1) and oxalate (1.26–4.41mgg−1) concentrations were also influenced by genotype. Antinutritional factors to minerals molar ratio were also significantly different by genotypes but were below the threshold for low mineral bioavailability. Genotype significantly influenced mineral and antinutritional concentrations of finger millet grains. In addition, all finger millet genotypes possess good mineral bioavailability. Especially, the high Ca concentration in finger millet, compared to in other cereals, could play a vital role to combating Ca deficiency. The result suggests the different finger millet genotypes possess good nutrient content and may contribute to the nutrition security of the local people
    corecore