24 research outputs found
Aluminum Fixed Point: Impact of the Time Spent in the Liquid Phase on the Liquid–Solid Transition and Obviousness of the Pollution of the Ingot
EURAMET.T-K7 key comparison of water triple point cells
The results of a EURAMET key comparison of water triple-point cells
(EURAMET.T-K7) are reported. The equipment used, the measuring conditions applied, and the procedures adopted for the water triple-point measurement at the
participating laboratories are synthetically presented. The definitions of the national
reference for the water triple-point temperature adopted by each laboratory are disclosed.
The multiplicity of degrees of equivalence arising for the linking laboratories
with respect to the “mother” comparison CCT-K7 is discussed in detail
Incertitudes de mesure: Applications concrètes pour les étalonnages
Les besoins de la société moderne, basée sur la technologie, nécessitent toutes sortes de mesures. Tout résultat de mesure n\u27est en général qu\u27une estimation de la valeur de la "vraie" valeur reste inconnue. L\u27estimation des incertitudes de mesure dans l\u27industrie ou dans les laboratoires est loin d\u27être maîtrisée de façon complète. Ce premier tome présente concrètement les procédures adaptées pour la thermométrie, le pesage et la mesure dimensionnelle. Les auteurs ont souhaité être pragmatiques et utiles dans leurs approches. Ainsi, chaque application peut servir de guide pour estimer l\u27incertitude de mesure d\u27un capteur thermométrique, d\u27un poids, d\u27une balance ou d\u27un interféromètre laser. Les parties sont suffisamment détaillées et justifiées de façon à ce que tous les lecteurs (enseignants, chercheurs, ingénieurs, techniciens, étudiants...) puissent s\u27en inspirer pour déterminer une incertitude de mesure quel que soit le domaine de mesure. Le deuxième tome complète ce premier en montrant qu\u27il est possible également d\u27estimer une incertitude de mesure même pour des mesures "difficiles" pratiquées par exemple dans les analyses médicales et agroalimentaires, et dans les essais électromagnétiques ou acoustiques, etc
Final report on EUROMET.TK4 (EUROMET Project 820): Comparison of the realizations of the ITS90 at the freezing points of Al (660.323 °C) and Ag (961.78 °C)
KEY COMPARISON: The comparison EUROMET.T-K4 is the regional extension of CCT-K4: an intercomparison of the realisations of the freezing points of Al (660.323 °C) and Ag (961.78 °C). The intercomparison was organized in four loops with long stem standard platinum resistance thermometers (SPRTs) as travelling standards: One 25 O thermometer to be used only at the Al freezing point and two high temperature SPRTs to be used only at the Ag freezing point in each loop. Parallel to the measurements with thermometers the pilot and sub-pilots organized an internal intercomparison using an Ag fixed point cell. Most HTSPRTs showed a strong drift which is mainly due to mechanical stress and poisoning of the sensor by impurities. This drift can partly be compensated by a correction applying Matthiessen's rule. An evaluation of the data taking into account both HTSPRTs in each loop, the linkage of the sub-pilots by measurements at the Ag freezing point and a possible compensation according to Matthiessens's rule allows to calculate the results of the participants also for the measurements at the Ag freezing point. European reference values (ERV) were calculated for measurements at the Al and Ag freezing points. The difference between these ERVs and the corresponding KCRVs of CCT-K4 is also given, which allows the linking of the different comparisons