1,720,966 research outputs found
Effectiveness of diclofenac eyedrops in reducing postoperative inflammation and angiographic CME after cataract surgery
Reproducibility of retinal nerve fiber layer evaluation by dynamics scanning laser ophthalmoscopy
Scanning laser ophthalmoscopy is a laser-based image acquisition technique, which greatly improves the quality of the examination of the fundus and the retinal nerve fiber layer. To assess retinal nerve fiber layer imaging by scanning laser ophthalmoscopy and evaluate intra- and interobserver reproducibility in the classification of retinal nerve fiber layer defects, three independent observers evaluated on two separate occasions the videotaped images of 150 eyes of 80 consecutive patients with ocular hypertension or glaucoma. Ophthalmoscopy was performed using argon blue light (488 nm), confocal apertures of 3 to 1 mm, and 40-degree and 20-degree field angles. Of 150 eyes, 20 (13.3%) were excluded from the study because of the poor quality of the images (clinically significant cataract or myopic peripapillary atrophy). The retinal nerve fiber layer was evaluated qualitatively according to a standard classification: normal pattern, slit, wedge, and diffuse defects. Intraobserver reproducibility, evaluated by kappa statistic, was excellent (> or = 0.75): observer A = 0.78 (95% confidence limits, 0.67-0.88); observer B = 0.84 (95% confidence limits, 0.72-0.96); and observer C = 0.79 (95% confidence limits, 0.67-0.91). Interobserver reproducibility was also excellent in all cases: observers A-B = 0.84 (95% confidence limits, 0.71-0.98); observers A-C = 0.76 (95% confidence limits, 0.65-0.87); and observers B-C = 0.80 (95% confidence limits, 0.69-0.92). Kappa values ranged between 0.59 and 0.69 for intraobserver reproducibility and between 0.55 and 0.69 for interobserver reproducibility when using only those eyes in which abnormalities were noted by at least one observe
The efficacy of the combination of l-moprolol and dipivefrin in reducing the intraocular pressure in primary open-angle glaucoma or in ocular hypertension
BACKGROUND: In this double-blind prospective trial the efficacy of lowering the intraocular pressure of l-moprolol given alone and in combination with dipivefrin was tested.
METHODS: Twenty-seven patients with primary open-angle glaucoma or ocular hypertension were randomly assigned to receive twice-daily l-moprolol eye drops or dipivefrin eye drops for 4 weeks; in a second phase of the trial, the combination of the two drugs was administered for 4 weeks.
RESULTS: The results of this study indicated that l-moprolol and dipivefrin had an equivalent effect in lowering the intraocular pressure. The association of the two drugs caused a further reduction of intraocular pressure which was significant only in the group previously treated with dipivefrin alone.
CONCLUSION: This trial demonstrated that the combination of l-moprolol and dipivefrin is an effective and safe treatment for elevated intraocular pressure
Effectiveness of diclofenac eyedrops in reducing inflammation and the incidence of cystoid macular edema after cataract surgery
PURPOSE: To evaluate the effectiveness of diclofenac eyedrops in reducing inflammation and the incidence of angiographic cystoid macular edema (CME) after cataract surgery and intraocular lens (IOL) implantation.
SETTING: Eye Clinic, Institute of Biomedical Sciences, San Paolo Hospital, Milan, Italy.
METHODS: Eighty-eight patients having cataract extraction were enrolled in a randomized clinical trial: 42 were given diclofenac eyedrops and 46, placebo. Postoperative inflammation in both groups was graded for 6 months using a dedicated system.
RESULTS: Eight patients (9%) had evidence of angiographic CME approximately 1 month after surgery: seven of these were in the placebo group (P = .039). This difference was not significant 3 and 6 months postoperatively. The signs of ocular inflammation were greater in the eyes receiving placebo; the difference was particularly evident up to 1 week after surgery. There was no significant difference in visual acuity between the two groups at any follow-up point, but the contrast sensitivity of the eyes that received diclofenac improved significantly at 10.5 cycles per degree 1 month postoperatively.
CONCLUSION: Diclofenac eyedrops effectively reduced ocular inflammation and the occurrence of angiographic CME after cataract surgery
I parametri morfometrici della papilla ottica : correlazione con sesso e lunghezza assiale del bulbo oculare
Curve ROC nella relazione tra indici perimetrici ed identificazione dei difetti delle fibre nervose retiniche nel glaucoma cronico semplice
Sensitivity and specificity of visual field indexes and optic disc morphometry in the assessment of glaucomatous RNFL defects
L'analisi delle fibre nervose retiniche mediante oftalmoscopia dinamica a scansione laser nella diagnosi del glaucoma cronico semplice : riproducibilità del metodo
Correlazione tra la morfometria della papilla ottica e difetti dello strato delle fibre nervose retiniche (RNFL) nel glaucoma cronico semplice
- …
