1,720,962 research outputs found
An enhanced model for the design of Diffusion Absorption Refrigerators
A steady state description of the thermal pump driving the Diffusion Absorption Refrigerator was integrated in the model previously proposed by the same authors. The thermal pump allows the DAR cycle to be activated, moving the strong mixture and separating the refrigerant from the weak one. So, the design parameters play a primary role in the DAR cycle performance in terms of COP. The enhanced model results were validated on a prototype built coupling a domestic 750 W-magnetron on a small purposely modified commercial DAR to activate the thermal pump. A maximum mismatch of 2.32% in the weak mixture mass flow rate and lower than 5% in COP between the predicted and measured data were found.
The microwaves activated thermal pump produced a distinct reduction in the starting transient time of the refrigerator and for this reason it can be proposed as a valid candidate to be used as a rapid cooler in small refrigeration applications
Refrigerazione ad assorbimento
Nel caso di impianti in cui si disponga di cascami termici o di energia termica a basso costo, in alcune situazioni, per esempio quando per i motivi più diversi non siano utilizzabili le macchine frigorifere tradizionali, la tecnologia ad assorbimento può giocare un ruolo decisivo nel soddisfare la richiesta di potenza frigorifera. La possibilità che le macchine ad assorbimento possano essere alimentate ad energia da fonte solare o con il calore di combustione della biomassa lascia intravedere anche la possibilità di applicazioni di grande interesse in termini di risparmio di combustibile fossile e quindi di riduzione delle emissioni inquinanti in atmosfera.
Il testo, partendo da una descrizione dettagliata dei fondamenti teorici e dei modelli di calcolo analitico delle prestazioni dei componenti delle macchine e dei sistemi esistenti, si pone l'obiettivo di riassumere lo stato dell'arte del settore, passando dalle soluzioni più semplici e comuni a quelle con ancora sperimentate nella pratica impiantistica. Brevetti, schemi funzionali delle macchine prodotte dai vari costruttori mondiali, accorgimenti tecnici adottati, controlli del ciclo termodinamico, operazioni di gestione e manutenzione, approfondimenti sulle numerose applicazioni dei refrigeratori e così via vengono trattati in maniera sistematica. L'ultimo capitolo è dedicato alla refrigerazione per adsorbimento che, pur essendo dal punto di vista teorico simile a quella ad assorbimento, se ne differenzia per l'applicazione a livello impiantistico e realizzativo
Fisica Tecnica
Basi della termodinamica - Cicli termodinamici - Aria umida - Trasmissione del calor
Bonifica acustica/2 – Progettazione e verifica per risanare
Descrive la metodologia e i risultati della progettazione avanzata di una bonifica acustica di un capannone adibito ad uso tessile.
Sfrutta ed elabora i risultati sperimentali raccolti sui telai di produzione con tecnica intensimetrica
Bonifica acustica/1 – La tecnica intensimetrica per caratterizzare le sorgenti sonore
Descrive i risultati di una campagna sperimentale di caratterizzazione di telai piani di produzione svolta a fini di bonifica di un capannone industriale e con tecnica intensimetrica
Test results and empirical correlations to account for air permeability of agricultural nets
Fifteen HDPE agricultural nets were tested inside a micro wind tunnel (0.1345 m diameter) to establish their characteristic air flow rate vs pressure drop curves with velocities >4 m s−1. The air pressure drop through the net was accounted for, with reference to the Bernoulli scheme, by means of the loss coefficient. Experimental results confirmed those available in the literature, in terms of the dependence of the pressure drop on the velocity squared and the net porosity, ε, by means of the function h(ε)=(1−ε2/ε2). The influence of the orifice geometry was investigated and an effect equivalent to the increase in net porosity was identified in textile pores with elongated shapes. As with previous studies, the loss coefficient trend was found to fit the product of two functions, one depending on the porosity, and the other on the Reynolds number defined using the pore equivalent diameter. The calculated values of the loss coefficient show deviations from experimental results in the range of 19.9–41.1%. In addition, a new formulation for the loss coefficient, dependent only on the porosity and wet perimeter was proposed. Except for higher porosity nets the simplified formulation, showed the best match with the experimental data. The two formulations of the loss coefficient proposed here were compared with those found in the literature
The Diffusion Absorption Refrigerator operation and performance
This chapter focuses on the Diffusion Absorption Refrigerator (DAR) cycle and describes a new advanced thermodynamic model which allows good predictions of the chiller performance in terms of efficiency and cooling capacity, starting from a precise evaluation of the thermo-physical properties of the working mixture at each point of the circuit. A steady state thermodynamic analytical model of the thermal pump driving the DAR is also included. In addition, the experimental validation of the model, performed on a prototype built coupling a domestic 750 W-magnetron with a small purposely modified commercial DAR to activate the thermal pump, is here included: a maximum mismatch of 2.32% in the weak mixture mass flow rate and lower than 5% in COP between the predicted and measured data were found
- …