11 research outputs found

    Residenze Universitarie inclusive e accessibili. Il progetto del recupero del compendio architettonico “Lina Meneghetti” a Padova

    No full text
    The 'Lina Meneghetti' architectural complex, consisting of a 16th-century building of considerable historical-architectural value, flanked by, and connected to, a 1950s building, was the subject of a restoration and refunctionalization project to be used as a residence for university students. The integration of design disciplines, restoration, structural engineering and plant engineering technologies has allowed the development of a proposal capable of guiding the design choices through a multidisciplinary approach aimed at the functionality of a specialized typology and, at the same time, at the conservation and enhancement of the historical-artistic heritage. The contribution reports the main phases of the case study with particular attention to the urban and social quality in relation to the inclusiveness of the historical building in the city centre. The experience was approached with the awareness that a residential structure, in order to be truly inclusive, must allow all users to move and orient themselves independently and safely

    Comparative Safety of Originator and Biosimilar Epoetin Alfa Drugs: An Observational Prospective Multicenter Study

    No full text
    Background: Erythropoiesis-stimulating agents (ESAs) are biological molecules approved for the treatment of anemia associated with chronic renal failure. Biosimilars were licensed for use in Europe in 2007. Aim: This study aimed to compare the safety profile of biosimilars with respect to the reference product in a nephrology setting. Methods: A prospective study was conducted in four Italian regions between 1 October 2013 and 30 June 2015. The study population included patients aged ≥ 18 years undergoing hemodialysis and treated with epoetins as per the clinical practice of the participating centers. The two comparison cohorts included patients treated with either an originator or a biosimilar epoetin alfa. Each patient was followed up until occurrence of any safety outcome of interest (grouped into three major categories), switch to a different ESA product, transplant or peritoneal dialysis, death, or end of the study period, whichever came first. Results: Overall, 867 subjects were included in the study (originator: N = 423; biosimilar: N = 444). Biosimilar users were older than originator users (median age of 76 vs 64 years, respectively), more frequently affected by arrhythmia (29.3 vs 22.5%), and less frequently candidates for transplantation (3.8 vs 18.2%). Cox-regression analysis showed no increase in risk of safety outcomes in biosimilar users, even after adjusting for confounding factors: 1.0 (95% confidence interval [CI] 0.7–1.3) for any outcomes; 1.1 (95% CI 0.7–1.8) for problems related to dialysis device; 0.9 (95% CI 0.6–1.5) for cardio- and cerebro-vascular conditions; 0.9 (95% CI 0.6–1.5) for infections. Conclusion: This study confirms the comparable safety profiles of originator and biosimilar epoetin alfa drugs when used in patients receiving dialysis

    Implementation and performances of the IPbus protocol for the JUNO Large-PMT readout electronics

    No full text
    The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. Thanks to the tight requirements on its optical and radio-purity properties, it will be able to perform leading measurements detecting terrestrial and astrophysical neutrinos in a wide energy range from tens of keV to hundreds of MeV. A key requirement for the success of the experiment is an unprecedented 3% energy resolution, guaranteed by its large active mass (20 kton) and the use of more than 20,000 20-inch photo-multiplier tubes (PMTs) acquired by high-speed, high-resolution sampling electronics located very close to the PMTs. As the Front-End and Read-Out electronics is expected to continuously run underwater for 30 years, a reliable readout acquisition system capable of handling the timestamped data stream coming from the Large-PMTs and permitting to simultaneously monitor and operate remotely the inaccessible electronics had to be developed. In this contribution, the firmware and hardware implementation of the IPbus based readout protocol will be presented, together with the performances measured on final modules during the mass production of the electronics

    Mass testing of the JUNO experiment 20-inch PMTs readout electronics

    No full text
    The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose, large size, liquid scintillator experiment under construction in China. JUNO will perform leading measurements detecting neutrinos from different sources (reactor, terrestrial and astrophysical neutrinos) covering a wide energy range (from 200 keV to several GeV). This paper focuses on the design and development of a test protocol for the 20-inch PMT underwater readout electronics, performed in parallel to the mass production line. In a time period of about ten months, a total number of 6950 electronic boards were tested with an acceptance yield of 99.1%
    corecore