Lo Studio TAC dell’Articolazione Femoro-Rotulea: Ottimizzazione del Protocollo di Lione.
Patellofemoral Syndrome: Update on CT Evaluation and Internal Derotation of the Anterior Tibial Tuberosity with the Use of Norian
Angiosonography in suspicious breast lesions with non-diagnostic FNAC: comparison with power Doppler US.
PURPOSE: The purpose of this study was to evaluate the accuracy of angiosonography in comparison with colour Doppler ultrasound (US) in the discrimination of suspicious breast lesions with nondiagnostic fine-needle aspiration cytology (FNAC).
MATERIALS AND METHODS: Pre-operative Power Doppler US and angiosonography were prospectively performed in 20 suspicious breast lesions with non-diagnostic FNAC. A second-generation US contrast agent was utilised with a high-frequency transducer and a contrast-specific algorithm (low acoustic pressure CnTI). The enhancement characteristics of all lesions were analysed using qualitative and quantitative parameters obtained from time-intensity curves with the different imaging modalities. The final diagnosis was confirmed at pathology in all cases. Microvessel density (MVD) was assessed in the surgical specimen using CD34.
RESULTS: The correct assessment of biological behaviour was achieved in all cases by angiosonography (sensitivity of 100%; specificity of 91%) and colour Doppler US (45% sensitivity; 78% specificity). MVD correlated with the biological behaviour.
CONCLUSIONS: Angiosonography is more accurate than colour Doppler US in the correct assessment of biological behaviour of suspicious breast lesion
[Digital radiography of the thorax with selenium detector. Clinical results and optimization potential of the technique]
INTRODUCTION: We compared the image quality of the chest radiograph obtained with a digital selenium detector and with a conventional system and investigated the possible improvements in the digital technique resulting from kilovoltage (kV) lowering, antiscattering grid addition and image format reduction.
MATERIAL AND METHODS: 150 subjects in the first series were submitted to posteroanterior chest radiography with both the selenium and the conventional systems. Image quality was compared by giving a score to the depiction of anatominal and pathologic findings. Thirty-two and 31 subjects from two other series were submitted to two digital chest radiographs each: the former at high (150) and low (90) kV, and the latter at 150 kV with the antiscattering grid and at 90 kV without the grid. Comparisons were made by choosing the better of the two images of each subjects. A score was given to the depiction quality of several difficult-to-detect findings in full-size and small-size format digital images obtained in another series of 27 subjects.
RESULTS: As for anatomical detailing, digital selenium images were of much better quality than conventional images: the mean scores given by 3 observers to digital images (5.32; 5.55; 6.68) are higher than those given to the corresponding conventional images (4.49; 5.02; 5.81) and the difference is statistically significant (p < 0.001 in all cases). The advantage of digital over conventional images is also significant with reference to diagnostic confidence in the identification of pathologic findings (p < 0.001; p < 0.005; p < 0.01), but to a lessere extent (mean scores: 3.98; 4.22; 3.60 for the digital system, versus 3.43; 3.69; 3.38 for the conventional system). The digital images acquired at lower kV (90 kV) were much more frequently chosen by the two observes (87.5% and 96.8% of cases) than the images acquired at 150 kV; the entry dose at lower energies (91 muGy using an anthropomorphic phantom) is not significantly higher than the dose given at 150 kV (85 muGy). No significant difference was found in the two observers' choice between the digital images taken at 90 kV without antiscattering grid and those taken at 150 kV with the grid, the former being preferred in 38.7% and 58% of cases. The level of diagnostic confidence in the detailing of difficult-to-detect findings was slightly higher in full-size digital images (mean scores: 5.33 and 6.77) than in small-size ones (4.88 and 5.96).
DISCUSSION AND CONCLUSIONS: Digital selenium images always exibit better quality than conventional images: the difference is very marked relative to anatomical detailing and not so striking, though still significant, in showing pathologic findings. Digital selenium image quality can be improved relative to the manufacturer's guidelines (150 kV exposure with no grid), by lowering the kV and adding the antiscattering grid, without increasing patient exposure too much. Digital image format reduction allows cost containment without affecting diagnostic reliability
The role of high-field MR spectroscopy in the multiparametric evaluation of breast lesions
no availabl
3T MR spectroscopy in the multi-parametric MRI evaluation of breast lesions: a pattern recognition approach
poster B-125
- …