8,523 research outputs found
CAMERA – Mobility Report 1
This report is a result of research performed so far in the scope of the CAMERA Coordination and Support Action (CSA). In CAMERA, we investigate research initiatives from the past decade that focus on the European air transport system and its integration with other transport modes, with a special focus on addressing the customer experience and point of view. The focus of this report is the review of the research under FP7 and its successor, H2020, as these have supported a large number of research activities in air mobility in the last decade. Its objective is to analyse 158 selected research initiatives in European mobility research to determine their coverage of mobility challenges, identify potential gaps and form recommendations for future research initiatives. This is the first of four Annual Mobility Reports that CAMERA is planning to publish. It outlines the initial findings and describes the future efforts of this Coordination and Support Action
D4.1: Gaps, bottlenecks and results: the methodology
This deliverable presents the methodology that CAMERA will follow to produce an overview of the European transportation research field. This methodology is based on the analysis carried out, and, planned in WP3, including the output of the cluster analysis presented in D3.1 and D5.3
Characterization for high dynamic range imaging
In this paper we present a new practical camera characterization technique to improve color accuracy in high dynamic range (HDR) imaging. Camera characterization refers to the process of mapping device-dependent signals, such as digital camera RAW images, into a well-defined color space. This is a well-understood process for low dynamic range (LDR) imaging and is part of most digital cameras — usually mapping from the raw camera signal to the sRGB or Adobe RGB color space. This paper presents an efficient and accurate characterization method for high dynamic range imaging that extends previous methods originally designed for LDR imaging. We demonstrate that our characterization method is very accurate even in unknown illumination conditions, effectively turning a digital camera into a measurement device that measures physically accurate radiance values — both in terms of luminance and color — rivaling more expensive measurement instruments
SHui open data research platform
Data collected and revised by individual instutions of the Shui-Consortium. Publication by the EU-China Consortium SHui.For each data-file, the author (institution) of the file is given as “operator”.-- At project end, June 30th, 2022.-- For each data-file, the author/data owner for citation is given as “operator” and “contact”.-- Plot data as .csv; catchment data ad libitum.Spatial situation data: Plot data and catchment data available; country, latitude, and longitude coordinates given.-- Temporal situation data: Long-term and single-season data available. Start and end date for each data file given.CC BY-SA. No embargo. The release on the Shui download site and CSIC repository implies expiration of any embargo delivered by the data owner.Project Co-ordinators: Dr. Jose Alfonso Gómez Calero (Instituto de Agricultura Sostenible (IAS-CISC), Dr. Weifeng Xu (Fujian Agriculture and Forest University, FAFU).This data set contains data from the SHui open-data platform for sharing long-term agricultural experiments aimed to optimizing yield and soil and water. Data and additional material are available under https://shui.boku.ac.at/shui/public/startAlphanumeric data measured at hydrologic and agronomical experiments (e.g., plant development, soil properties, hydrology, erosion, management).Further information on the data, project, partners, and publications under https://www.shui-eu.org/EU-China Consortium SHui: European Union Project 773903 and Chinese MOST.Peer reviewe
Designable visual markers
Visual markers are graphic symbols designed to be easily recognised by machines. They are traditionally used to track goods, but there is increasing interest in their application to mobile HCI. By scanning a visual marker through a camera phone users can retrieve localised information and access mobile services.One missed opportunity in current visual marker systems is that the markers themselves cannot be visually designed, they are not expressive to humans, and thus fail to convey information before being scanned. This paper provides an overview of d-touch, an open source system that allows users to create their own markers, controlling their aesthetic qualities. The system runs in real-time on mobile phones and desktop computers. To increase computational efficiency d-touch imposes constraints on the design of the markers in terms of the relationship of dark and light regions in the symbols. We report a user study in which pairs of novice users generated between 3 and 27 valid and expressive markers within one hour of being introduced to the system, demonstrating its flexibility and ease of use
Enrichment and characterization of a bacteria consortium capable of heterotrophic nitrification and aerobic denitrification at low temperature
Nitrogen removal in wastewater treatment plants is usually severely inhibited under cold temperature. The present study proposes bioaugmentation using psychrotolerant heterotrophic nitrification-aerobic denitrification consortium to enhance nitrogen removal at low temperature. A functional consortium has been successfully enriched by stepped increase in DO concentration. Using this consortium, the specific removal rates of ammonia and nitrate at 10 degrees C reached as high as 3.1 mg N/(g SS h) and 9.6 mg N/ (g SS h), respectively. PCR-DGGE and clone library analysis both indicated a significant reduction in bacterial diversity during enrichment. Phylogenetic analysis based on nearly full-length 16S rRNA genes showed that Alphaproteobacteria. Deltaproteobacteria and particularly Bacteroidetes declined while Gammaproteobacteria (all clustered into Pseudomonas sp.) and Betaproteobacteria (mainly Rhodoferax ferrireducens) became dominant in the enriched consortium. It is likely that Pseudomonas spp. played a major role in nitrification and denitrification, while R. ferrireducens and its relatives utilized nitrate as both electron acceptor and nitrogen source. Crown Copyright (C) 2012 Published by Elsevier Ltd. All rights reserved.</p
A clustering based denoising technique for range images of time of flight cameras
A relatively new technique for measuring the 3D structure of visual scenes is provided by time of flight (TOF) cameras. Reflections of modulated light waves are recorded by a parallel pixel array structure. The time series at each pixel of the resulting image stream is used to estimate travelling time and thus range information. This measuring technique results in pixel dependent noise levels with variances changing over several orders of magnitude dependent on the illumination and material parameters. This makes application of traditional (global) denoising techniques suboptimal. Using free aditional information from the camera and a clustering procedure we can get information about which pixels belong to the same object, and what their noise level is, which allows for locally adapted smoothing. To illustrate the success of this method, we compare it with raw camera output and a traditional method for edge preserving smoothing, anisotropic diffusion [10, 12]. We show that this mathematical technique works without individual adaptations on two camera systems with highly different noise characteristics
Arabic Treebank : Part 2 v 3.1
Arabic Treebank: Part 2 (ATB2) v 3.1 , Linguistic Data Consortium (LDC) catalog number LDC2011T09 and isbn 1-58563-590-1, was developed at LDC. It consists of 501 newswire stories from Ummah Press with part-of-speech (POS), morphology, gloss and syntactic treebank annotation in accordance with the Penn Arabic Treebank (PATB) Guidelines developed in 2008 and 2009
Publisher Correction: Multiancestry genome-wide association study of 520,000 subjects identifies 32 loci associated with stroke and stroke subtypes (Nature Genetics, (2018), 50, 4, (524-537), 10.1038/s41588-018-0058-3)
In the HTML version of this article initially published, the author groups ‘AFGen Consortium’, ‘Cohorts for Heart and Aging Research in Genomic Epidemiology (CHARGE) Consortium’, ‘International Genomics of Blood Pressure (iGEN-BP) Consortium’, ‘INVENT Consortium’, ‘STARNET’, ‘BioBank Japan Cooperative Hospital Group’, ‘COMPASS Consortium’, ‘EPIC-CVD Consortium’, ‘EPIC-InterAct Consortium’, ‘International Stroke Genetics Consortium (ISGC)’, ‘METASTROKE Consortium’, ‘Neurology Working Group of the CHARGE Consortium’, ‘NINDS Stroke Genetics Network (SiGN)’, ‘UK Young Lacunar DNA Study’ and ‘MEGASTROKE Consortium’ appeared at the end of the author list but should have appeared earlier in the list. In addition, the author group ‘MEGASTROKE Consortium’ was duplicated, and its members were not displayed in the ‘Author information’ section. The errors have been corrected in the HTML version of the article
8K ultra-high-definition microscopic camera for ophthalmic surgery
Hiromasa Yamashita,1,2 Kenkichi Tanioka,2 Goichiro Miyake,3 Ichiro Ota,3 Toru Noda,4 Kensaku Miyake,3 Toshio Chiba1,2 1Kairos Co. Ltd., Tokyo, Japan; 2Medical Imaging Consortium, Tokyo, Japan; 3Miyake Eye Hospital, Nagoya, Japan; 4Tokyo Medical Center, Tokyo, Japan Background: We have developed a new compact lightweight 8K ultra-high-definition (UHD; 7,680×4,320 pixels) camera and started medical application with an ophthalmic surgical microscope which is interchangeable with the conventional high-definition (1,920×1,080 pixels)/4K UHD (3,840×2,160 pixels) microscopic camera. Methods: We did a feasibility study to apply our 8K UHD microscope in cataract surgery, glaucoma surgery and vitreous surgery using pig cadaver eyes. The 8K UHD microscope comprises a surgical microscope, a camera adaptor with relay lenses, an 8K UHD camera and an 8K UHD LCD to share the 8K UHD images with all surgical staff in real time. Results: In ophthalmic surgeries, higher resolution images than conventional microscopic cameras were obtained with 8K UHD LCD equivalent to the observation through the microscopic eye pieces. Conclusion: Based on the results of this feasibility study, clinical trials on human ophthalmic surgery using the new 8K UHD microscopic camera should be conducted in the near future. Keywords: 8K ultra-high-definition camera, surgical microscope, cataract surgery, glaucoma surgery, vitreoretinal surgery, heads-up surger
- …
