20 research outputs found
Electric Power System Anomaly Detection Using Neural Networks
Wellington, New Zealand, Lecture Notes in Artificial Intelligenc
Contemporary balloon aortic valvuloplasty: Changing indications and refined technique
Even if unable to improve long-term prognosis, balloon aortic valvuloplasty (BAV) may be useful in selected patients with symptomatic severe aortic stenosis either as a bridge to surgical or transcatheter valve replacement (aortic valve replacement [AVR] or transcatheter aortic valve implantation [TAVI]) or as a triage strategy for patients with uncertain indications. International guidelines recommend BAV as: a “bridge” to AVR/TAVI, a “trial” in patients with undetermined symptoms, or a “bridge-to-decision” in case of comorbidities. However, in clinical practice, BAV is also used as a palliative measure to improve hemodynamics and quality of life in many patients who are excluded from AVR/TAVI. Finally, BAV is often performed during TAVI to facilitate prosthesis delivery, optimize frame expansion, or for bioprosthetic valve fracture in selected valve-in-valve procedures. Technical innovations, which allow for a mini-invasive approach via transradial access and pacing delivered through the wire, have led to a decrease in complications over time. This review focuses on contemporary BAV with a specific emphasis on new indications, innovative techniques, and specific complex patient subgroups
Prevention in coronary postangioplasty restenosis with omega-3 fatty acids. Results of the Italian study on prevention of restenosis with esapent (ESPRIT)
Transcatheter Aortic Valve Replacement Without On-Site Cardiac Surgery: Ready for Prime Time?
No abstract availabl
Urine-Derived Renal Epithelial Cells (URECs) from Transplanted Kidneys as a Promising Immunomodulatory Cell Population
Kidney transplantation is a lifesaving procedure for patients with end-stage kidney disease (ESKD). Organs derived from donation after cardiac death (DCD) are constantly increasing; however, DCD often leads to ischaemia-reperfusion (IR) and Acute Kidney Injury (AKI) events. These phenomena increase kidney cell turnover to replace damaged cells, which are voided in urine. Urine-derived renal epithelial cells (URECs) are rarely present in the urine of healthy subjects, and their loss has been associated with several kidney disorders. The present study aimed to characterize the phenotype and potential applications of URECs voided after transplant. The results indicate that URECs are highly proliferating cells, expressing several kidney markers, including markers of kidney epithelial progenitor cells. Since the regulation of the immune response is crucial in organ transplantation and new immunoregulatory strategies are needed, UREC immunomodulatory properties were investigated. Co-culture with peripheral blood mononuclear cells (PBMCs) revealed that URECs reduced PBMC apoptosis, inhibited lymphocyte proliferation, increased T regulatory (Treg) cells and reduced T helper 1 (Th1) cells. URECs from transplanted patients represent a promising cell source for the investigation of regenerative processes occurring in kidneys, and for cell-therapy applications based on the regulation of the immune response
Minimal effective concentration values of propafenone and 5-hydroxy-propafenone in acute and chronic therapy
We evaluated the antiarrhythmic efficacy and the minimal effective concentrations of propafenone and its metabolite 5-hydroxy-propafenone during a) acute intravenous infusion (1.5 mg/kg in bolus followed by 45 minutes infusion), b) an acute oral single-dose test (450 mg), and c) 14-day chronic therapy (300 mg tid) followed by a washout. Oxidative metabolism was assessed by a debrisoquine oral test in every patient. Eleven patients with stable ventricular premature beats (VPBs) greater than or equal to 300/hr and Lown class greater than or equal to 3 completed the study. The main results emphasized a certain discrepancy between the clinical effect of the acute intravenous infusion (efficacy in 5 out of 11 patients) and of the acute oral test and chronic therapy (efficacy in 11/11), with a time lag of the ECG changes during the acute intravenous infusion. The minimal effective concentrations were lower after acute oral administration compared with chronic treatment both for propafenone (200 +/- 189 ng/ml vs. 492 +/- 530 ng/ml; p less than 0.05) and for 5-hydroxy-propafenone (82 +/- 40 ng/ml vs. 149 +/- 80 ng/ml; p less than 0.02). A linear correlation was demonstrated between drug/metabolite ratios of propafenone and debrisoquine, either after acute oral (r = 0.91) or after chronic administration (r = 0.84). The pharmacokinetics of propafenone was nonlinear and showed wide interindividual variations.(ABSTRACT TRUNCATED AT 250 WORDS
Comparison of effectiveness and safety of sirolimus-eluting stents versus bare-metal stents in patients with diabetes mellitus (from the Italian multicenter randomized DESSERT study)
Few studies directly compared drug-eluting stents and bare-metal stents (BMSs) in diabetic patients. DESSERT was an Italian multicenter randomized trial to show the efficacy of sirolimus-eluting stents (SESs) compared with BMSs in de novo lesions of diabetic patients treated with insulin and/or oral antidiabetics for >= 3 months on top of glycoprotein IIb/IIIa inhibitors. The primary end point was in-stent late lumen loss, assessed using centralized quantitative coronary angiography at 8-month follow-up. Centrally adjudicated composite major adverse cardiac events (MACEs) and target-vessel failure (TVF; death, treated vessel-related acute myocardial infarction, and target-vessel revascularization) at 30 days and 9 and 12 months were secondary end points. Seventy-five patients were randomly assigned to an SES (109 lesions), and 75 (109 lesions), to a BMS. The 2 groups were well balanced for clinical, anatomic, and procedural characteristics. In-stent late lumen loss decreased from 0.96 +/- 0.61 nun for BMSs to 0.14 +/- 0.33 for SESs (p < 0.001), and in-segment binary restenosis was 38.8% versus 3.6%, respectively (p < 0.001). Twelve-month clinical events were significantly lower in the sirolimus group: MACEs 22.1 % versus 40% (p = 0.023), target-lesion revascularization 5.9% versus 30% (p < 0.001), and TVF 14.7% versus 34.3% (p = 0.008). At multivariate analysis, stent type was confirmed as an independent predictor of in-segment late loss (p < 0.001), binary restenosis (p < 0.001), 12-month TVF (p = 0.010), and 12-month MACEs (p = 0.037). In conclusion, the randomized DESSERT showed SESs to be safe and effective in decreasing both angiographic parameters of restenosis and incidence of MACEs compared with BMSs in diabetic patients with de novo 1- or 2-vessel coronary stenoses. (c) 2008 Elsevier Inc. All rights reserved
Genetic agents in an EDSS system to optimize resources management and risk object evacuation
NUMERICAL AND SYMBOLIC MODELING TECHNIQUES APPLIED TO IMPROVE THE OPERATOR EFFICIENCY OF ALLUMINIUM SMELTERS
Aortic balloon valvuloplasty outcome according to calcium distribution and valve geometry – The ABCD study
Background: There is little data on the outcome of balloon aortic valvuloplasty (BAV) in relation to valve dimensions and calcification patterns. The procedure is not standardized, particularly the choice of balloon size. Methods: This retrospective multicenter study focused on BAV efficacy and safety by analyzing the relationship between balloon size, annulus geometry (i.e., diameters, perimeter, and area), and calcification patterns (total burden and calcium distribution over each individual leaflet). From March 2018 to March 2023, all consecutive patients who underwent clinically indicated BAV and ECG-gated multidetector computed tomography of the aorta were included, except those with a bicuspid valve. Calcium score was calculated on contrast-enhanced images based on a luminal attenuation threshold of +100 HU. Results: One hundred and fifteen patients were included. Procedural success was 82.6 %. The balloon-to-annulus ratio (BAR) relative to diameter, perimeter, and area was higher in patients with successful BAV. Patients with unsuccessful BAV had a significantly higher aortic valve calcium burden. The complication rate was 4.3 % and there was no association with valve geometry or calcium burden. A trend towards a reduced complication rate was found as calcium asymmetry increased. BAR minimum annulus diameter was the best parameter in predicting procedural success, with a cut-off at 0.85. Conclusions: BAV efficacy is correlated directly with balloon size in relation to annulus dimension and inversely with total calcium burden. The minimum diameter of the valve may be adopted as a reference for balloon sizing
