1,721,077 research outputs found

    Reply to Grace: Role of cholinergic neurons in rapid eye movement (REM) sleep control

    Get PDF
    We thank Grace (1) for the opportunity to discuss the role of cholinergic neurons in rapid eye movement (REM) sleep further. Grace suggests that optogenetic activation of a population of neurons does not necessarily demonstrate their role in the endogenous system when interrogating complex neural circuitry. We agree that we do not prove necessity of cholinergic neurons in REM sleep generation, as we point out in our discussion, “Future studies that selectively inhibit cholinergic neurons in the PPT [pedunculopontine tegmentum] and LDT [laterodorsal tegmentum] of nonhypercholinergic mice are needed to determine if cholinergic neurons are necessary for REM sleep generation” (2). However, in our report we do demonstrate the sufficiency of PPT/LDT neurons to influence REM sleep initiation but not influence REM sleep duration, thus distinguishing the role of cholinergic neurons on these properties of REM sleep. In addition, activation of cholinergic PPT neurons during non-REM sleep induced REM sleep versus wakefulness. Our data are consistent with the role of cholinergic neurons in generating an activated brain state and many studies pointing to the role of cholinergic neurons in REM sleep regulation (reviewed in ref. 3)

    The human burst suppression electroencephalogram of deep hypothermia

    Get PDF
    Objective: Deep hypothermia induces 'burst suppression' (BS), an electroencephalogram pattern with low-voltage 'suppressions' alternating with high-voltage 'bursts'. Current understanding of BS comes mainly from anesthesia studies, while hypothermia-induced BS has received little study. We set out to investigate the electroencephalogram changes induced by cooling the human brain through increasing depths of BS through isoelectricity. Methods: We recorded scalp electroencephalograms from eleven patients undergoing deep hypothermia during cardiac surgery with complete circulatory arrest, and analyzed these using methods of spectral analysis. Results: Within patients, the depth of BS systematically depends on the depth of hypothermia, though responses vary between patients except at temperature extremes. With decreasing temperature, burst lengths increase, and burst amplitudes and lengths decrease, while the spectral content of bursts remains constant. Conclusions: These findings support an existing theoretical model in which the common mechanism of burst suppression across diverse etiologies is the cyclical diffuse depletion of metabolic resources, and suggest the new hypothesis of local micro-network dropout to explain decreasing burst amplitudes at lower temperatures. Significance: These results pave the way for accurate noninvasive tracking of brain metabolic state during surgical procedures under deep hypothermia, and suggest new testable predictions about the network mechanisms underlying burst suppression.National Institutes of Health (U.S.) (Grant DP2-OD006454)National Institutes of Health (U.S.) (Grant DP1-OD003646)National Institutes of Health (U.S.) (Grant TR01-GM104948

    Sparse spectral estimation from point process observations

    Get PDF
    We consider the problem of estimating the power spectral density of the neural covariates underlying the spiking of a neuronal population. We assume the spiking of the neuronal ensemble to be described by Bernoulli statistics. Furthermore, we consider the conditional intensity function to be the logistic map of a second-order stationary process with sparse frequency content. Using the binary spiking data recorded from the population, we calculate the maximum a posteriori estimate of the power spectral density of the process while enforcing sparsity-promoting priors on the estimate. Using both simulated and clinically recorded data, we show that our method outperforms the existing methods for extracting a frequency domain representation from the spiking data of a neuronal population

    Controversy in statistical analysis of functional magnetic resonance imaging data

    Get PDF
    To test the validity of statistical methods for fMRI data analysis, Eklund et al. (1) used, for the first time, large-scale experimental data rather than simulated data. Using resting-state fMRI measurements to represent a null hypothesis of no task-induced activation, the authors compare familywise error rates for voxel-based and cluster-based inferences for both parametric and nonparametric methods. Eklund et al.’s study used three fMRI statistical analysis packages. They found that, for a target familywise error rate of 5%, the parametric methods gave invalid cluster-based inferences and conservative voxel-based inferences

    Spatial variation in automated burst suppression detection in pharmacologically induced coma

    Get PDF
    Burst suppression is actively studied as a control signal to guide anesthetic dosing in patients undergoing medically induced coma. The ability to automatically identify periods of EEG suppression and compactly summarize the depth of coma using the burst suppression probability (BSP) is crucial to effective and safe monitoring and control of medical coma. Current literature however does not explicitly account for the potential variation in burst suppression parameters across different scalp locations. In this study we analyzed standard 19-channel EEG recordings from 8 patients with refractory status epilepticus who underwent pharmacologically induced burst suppression as medical treatment for refractory seizures. We found that although burst suppression is generally considered a global phenomenon, BSP obtained using a previously validated algorithm varies systematically across different channels. A global representation of information from individual channels is proposed that takes into account the burst suppression characteristics recorded at multiple electrodes. BSP computed from this representative burst suppression pattern may be more resilient to noise and a better representation of the brain state of patients. Multichannel data integration may enhance the reliability of estimates of the depth of medical coma.National Institutes of Health (U.S.) (Grant K23 NS090900)National Institute of Neurological Diseases and Stroke (U.S.) (Grant K23 NS090900)National Institutes of Health (U.S.) (Grant DP2-OD006454)National Institutes of Health (U.S.) (Grant TROI-GMI04948

    Modeling two-photon calcium fluorescence of episodic V1 recordings using multifrequency analysis

    Get PDF
    The use of two-photon microscopy allows for imaging of deep neural tissue in vivo. This paper examines frequency-based analysis to two-photon calcium fluorescence images with the goal of deriving smooth tuning curves. We present a multifrequency analysis approach for improved extraction of calcium responses in episodic stimulation experiments, that is, when the stimulus is applied for a number of frames, then turned off for the next few frames, and so on. Episodic orientation stimulus was applied while recording from the primary visual cortex of an anesthetized mouse. The multifrequency model demonstrated improved tuning curve descriptions of the neurons. It also offers perspective regarding the characteristics of calcium fluorescence imaging of the brain.National Institutes of Health (U.S.) (Grant DP1-OD003646)National Institutes of Health (U.S.) (Grant R01-EB006385)National Institutes of Health (U.S.) (Grant EY07023)National Institutes of Health (U.S.) (Grant EY017098

    Clinical Electroencephalography for Anesthesiologists

    Get PDF
    The widely used electroencephalogram-based indices for depth-of-Anesthesia monitoring assume that the same index value defines the same level of unconsciousness for all anesthetics. In contrast, we show that different anesthetics act at different molecular targets and neural circuits to produce distinct brain states that are readily visible in the electroencephalogram. We present a two-part review to educate anesthesiologists on use of the unprocessed electroencephalogram and its spectrogram to track the brain states of patients receiving anesthesia care. Here in part I, we review the biophysics of the electroencephalogram and the neurophysiology of the electroencephalogram signatures of three intravenous anesthetics: propofol, dexmedetomidine, and ketamine, and four inhaled anesthetics: sevoflurane, isoflurane, desflurane, and nitrous oxide. Later in part II, we discuss patient management using these electroencephalogram signatures. Use of these electroencephalogram signatures suggests a neurophysiologically based paradigm for brain state monitoring of patients receiving anesthesia care.National Institutes of Health (U.S.) (Grant DP1-OD003646)National Institutes of Health (U.S.) (Grant TR01-GM104948

    Reference-free removal of EEG-fMRI ballistocardiogram artifacts with harmonic regression

    Get PDF
    Combining electroencephalogram (EEG) recording and functional magnetic resonance imaging (fMRI) offers the potential for imaging brain activity with high spatial and temporal resolution. This potential remains limited by the significant ballistocardiogram (BCG) artifacts induced in the EEG by cardiac pulsation-related head movement within the magnetic field. We model the BCG artifact using a harmonic basis, pose the artifact removal problem as a local harmonic regression analysis, and develop an efficient maximum likelihood algorithm to estimate and remove BCG artifacts. Our analysis paradigm accounts for time-frequency overlap between the BCG artifacts and neurophysiologic EEG signals, and tracks the spatiotemporal variations in both the artifact and the signal. We evaluate performance on: simulated oscillatory and evoked responses constructed with realistic artifacts; actual anesthesia-induced oscillatory recordings; and actual visual evoked potential recordings. In each case, the local harmonic regression analysis effectively removes the BCG artifacts, and recovers the neurophysiologic EEG signals. We further show that our algorithm outperforms commonly used reference-based and component analysis techniques, particularly in low SNR conditions, the presence of significant time-frequency overlap between the artifact and the signal, and/or large spatiotemporal variations in the BCG. Because our algorithm does not require reference signals and has low computational complexity, it offers a practical tool for removing BCG artifacts from EEG data recorded in combination with fMRI.National Institutes of Health (U.S.) (Award DP1-OD003646)National Institutes of Health (U.S.) (Award TR01-GM104948)National Institutes of Health (U.S.) (Grant R44NS071988)National Institute of Neurological Diseases and Stroke (U.S.) (Grant Grant R44NS071988

    Real-time segmentation and tracking of brain metabolic state in ICU EEG recordings of burst suppression

    Get PDF
    We provide a method for estimating brain metabolic state based on a reduced-order model of EEG burst suppression. The model, derived from previously suggested biophysical mechanisms of burst suppression, describes important electrophysiological features and provides a direct link to cerebral metabolic rate. We design and fit the estimation method from EEG recordings of burst suppression from a neurological intensive care unit and test it on real and synthetic data.National Institutes of Health (U.S.) (Grant DP1-OD003646

    A transient cortical state with sleep-like sensory responses precedes emergence from general anesthesia in humans

    Get PDF
    During awake consciousness, the brain intrinsically maintains a dynamical state in which it can coordinate complex responses to sensory input. How the brain reaches this state spontaneously is not known. General anesthesia provides a unique opportunity to examine how the human brain recovers its functional capabilities after profound unconsciousness. We used intracranial electrocorticography and scalp EEG in humans to track neural dynamics during emergence from propofol general anesthesia. We identify a distinct transient brain state that occurs immediately prior to recovery of behavioral responsiveness. This state is characterized by large, spatially distributed, slow sensory-evoked potentials that resemble the K-complexes that are hallmarks of stage two sleep. However, the ongoing spontaneous dynamics in this transitional state differ from sleep. These results identify an asymmetry in the neurophysiology of induction and emergence, as the emerging brain can enter a state with a sleep-like sensory blockade before regaining responsivity to arousing stimuli.National Institutes of Health (U.S.) (Grant K99-MH111748)National Institutes of Health (U.S.) (Grant R00-NS080911)National Institutes of Health (U.S.) (Grant DP2-OD006454)National Institutes of Health (U.S.) (Grant S10-RR023401)National Institutes of Health (U.S.) (Grant R01- NS062092)National Institutes of Health (U.S.) (Grant R01AG056015)National Institutes of Health (U.S.) (Grant P01GM118269)National Institutes of Health (U.S.) (Grant R01-EB009282
    corecore