1,720,967 research outputs found
Filtering to match hearing aid insertion gain to individual ear acoustics
When hearing aid gain is prescribed by software, gain is calculated based on the average acoustics for the age of patient, gender, mold type, and so on. The acoustics of the individual’s ear often vary from the average values, so there will be a mismatch between the prescribed gain and the real-ear gain. Real-ear measurement can be used to verify the gain and adjust it to meet targets, but the quality of the match will be limited by the number of channels and the flexibility of the hearing aid. A potential way to improve this process is to generate a filter that compensates for variations in real-ear insertion gain due to individual ear acoustics. Such a filter could be included in the processing path of a digital hearing aid. This article describes how such a filter can be generated using the windowing method, and the principle is demonstrated in a real ear. The approach requires communication between the real-ear measurement and hearing aid programming software. A finite impulse response filter with group delay just over 2 ms matched insertion gain to target values within the acceptable tolerance defined by British Society of Audiology guideline
Measuring real-ear signal-to-noise ratio: application to directional hearing aids
Due to individual characteristics such as head size, earmould type, and earmould venting, the directional benefit that an individual will obtain from a hearing aid cannot be predicted from average data. It is therefore desirable to measure real ear directional benefit. This paper demonstrates a method to measure real ear hearing aid directivity based on a general approach to measure the broadband output signal-to-noise ratio of a hearing aid. Errors arising from non-linearity were tested in simulation and found to be low for typical hearing aid compression ratios. Next, the efficacy of the method to estimate directional benefit was demonstrated on KEMAR. Finally the variability of directional benefit was explored in real-ears. Significant differences in signal-to-noise ratio between directional and omnidirectional microphone settings were demonstrated at most azimuths. Articulation-Index-weighted directional benefit varied by more than 7 dB across ears at some azimuths. Such individual variation in directional benefit has implications when fitting hearing aids: it should not be assumed that all users will receive similar directional benefit from the same hearing aid
Ocular vestibular evoked myogenic potentials elicited with vibration applied to the teeth
Objectives: This study investigated whether the method for eliciting vibration-induced oVEMPs could be improved by applying vibration directly to the teeth, and how vibration-induced oVEMP responses depend on the duration of the applied vibration.Methods: In 10 participants, a hand-held shaker was used to present 100-Hz vibration tone pips to the teeth via a customised bite-bar or to other parts of the head. oVEMP potentials were recorded in response to vibration in three orthogonal directions and five stimulus durations (10–180 ms). The oVEMP responses were analysed in terms of the peak latency onset, peak-to-peak amplitude, and the quality of the trace.Results: Vibration applied to the teeth via the bite-bar produced oVEMPs that were more consistent, of higher quality and of greater amplitude than those evoked by vibration applied to the head. Longer duration stimuli produced longer duration oVEMP responses. One cycle duration stimuli produced responses that were smaller in amplitude and lower quality than the longer stimulus durations.Conclusions: Application of vibration via the teeth using a bite-bar is an effective means of producing oVEMPs. A 1-cycle stimulus is not optimal to evoke an oVEMP because it produces less robust responses than those of longer stimulus duration. A positive relationship between the duration of the stimulus and the response is consistent with the notion that the vibration-induced oVEMP is an oscillatory response to the motion of the head, rather than being a simple reflex response that occurs when the stimulus exceeds a threshold level of stimulation.Significance Applying acceleration to the teeth through a bite-bar elicits clearer oVEMP responses than direct application to other parts of the head and has potential to improve clinical measurements. A 100-Hz 1-cycle stimulus produces less robust oVEMP responses than longer 100-Hz stimul
Vestibular evoked myogenic potential (VEMP) test-retest reliability in adults
Background: the technique of measuring ocular vestibular evoked myogenic potentials (oVEMP) in response to Mini-shaker vibration is relatively new, there is a limited normative data to define the presence or absence of a response in the literature.Objective: to determine the test-retest reliability of cervical and ocular VEMPs (cVEMP and oVEMP, respectively) to air-conducted sound (ACS) and bone-conducted vibration (BCV) stimulation and to determine normative ranges for the responses.Methods: twenty normal-hearing individuals (40 ears) and 20 hearing impaired volunteers with normal balance function (40 ears) were examined in this study. ACS cVEMP and BCV oVEMP (using a Mini-shaker) were recorded from both groups to assess the test-retest reliability and to collect normative VEMP data for P1/N1 latencies and amplitudes from 20 normal hearing individuals. To test reliability, VEMP recordings were repeated within the same session. RESULTS: The test-retest reliability for all the cVEMP parameters showed excellent reliability whereas oVEMP parameters showed between fair and excellent reliability depending on the parameter tested. Normative data for VEMP P1/N1 latencies and amplitudes were established.Conclusions: normative data and test-retest reliability for BCV oVEMP using the Mini-shaker at 100 Hz were established in our study for the first time in the literature. Responses appear reliable. <br/
Vestibular evoked myogenic responses to amplitude modulated sounds
Auditory Steady State Responses ASSR allow objective assessment of hearing thresholds. At high stimulation levels artifactual responses have been reported in subjects with severe to profound deafness. Relatively large amplitude ‘steady state’ responses to amplitude modulated tones were measured from the Sternocleidomastoid muscle at 500 Hz. Response thresholds were similar to those of Vestibular Evoked Myogenic Potentials and scaled with neck muscle tension. ‘Steady-state’ myogenic responses showed broad tuning to modulation frequency. Reduced amplitude responses were measured at the inion indicating volume conduction from the SCM. While dependant on neck tension, such responses are a potential source of artifacts when recording ASSR
Optimizing the acquisition time of the middle latency response using maximum length sequences and chirps
The middle latency response (MLR) may be used as an indicator of anesthetic depth but has been criticized due to its long acquisition time. This study explores methods for optimizing recording of the MLR to maximize signal-to-noise ratio (SNR) and hence reduce acquisition time. The first experiment investigates the effects of increasing stimulation rate beyond conventional values and also using higher rates by means of maximum length sequences (MLS). The second experiment compares the use of click and chirp stimuli to elicit the MLR, both at conventional and MLS stimulation rates. For all conditions total recording duration is fixed at 185 s and stimulation level is fixed at 60 dB SL. It was found that SNR increases progressively with rate using conventional click stimulation until the theoretical rate limit is reached at the reciprocal of the response duration. The SNR improvement is equivalent to increasing test speed by a factor of 3. Using MLS stimulation, the SNR increases further until a maximum is reached at a rate of 167 clicks/s, equivalent to a fivefold test speed improvement relative to a conventional recording at 5 clicks/s. The use of chirp stimuli designed to compensate for the frequency dependent cochlear traveling wave delay produces an increase in wave V-Na amplitude at all recording rates. For the later latency waves of the response an increase in amplitude is seen for MLS, but not for conventional chirp trains. The optimum SNR was obtained using chirp stimuli at a MLS rate of 167 opportunities/s. It is concluded that the combination of chirps and MLS can reduce acquisition time to less than one-tenth of that required for conventional stimulation at 5 clicks/s for the same SNR. This would confer material benefits for estimating anesthetic depth using MLR
The auditory middle latency response, evoked using maximum length sequences and chirps, as an indicator of adequacy of anesthesia
The auditory evoked potential known as the middle latency response (MLR), evoked with regular click stimulation at around 5 Hz, has been suggested as an indicator of adequacy of anesthesia. The MLR is a very small signal embedded in high levels of background noise, so it can take a long time to acquire. However, using a stimulus paradigm of chirps presented in a maximum length sequence, the acquisition of the MLR can be improved compared to using conventional click stimulation. In this pilot study, we investigated this new technique in a clinical environment. Significant changes in MLR amplitude, but not latency, were measured for six of seven subjects in association with changes in responsiveness to command using the isolated forearm technique. The absence of any latency shift differs from other studies of the MLR during anesthesia and highlights the limited understanding of the relationship between anesthesia and the MLR
Continuous speech with pauses inserted between words increases cortical tracking of speech envelope
The decoding multivariate Temporal Response Function (decoder) or speech envelope reconstruction approach is a well-known tool for assessing the cortical tracking of speech envelope. It is used to analyse the correlation between the speech stimulus and the neural response. It is known that auditory late responses are enhanced with longer gaps between stimuli, but it is not clear if this applies to the decoder, and whether the addition of gaps/ pauses in continuous speech could be used to increase the envelope reconstruction accuracy. We investigated this in normal hearing participants who listened to continuous speech with no added pauses (natural speech), and then with short (250 ms) or long (500 ms) silent pauses inserted between each word. The total duration for continuous speech stimulus with no, short, and long pauses were approximately, 10 minutes, 16 minutes, and 21 minutes, respectively. EEG and speech envelope were simultaneously acquired and then filtered into delta (1–4 Hz) and theta (4–8 Hz) frequency bands. In addition to analysing responses to the whole speech envelope, speech envelope was also segmented to focus response analysis on onset and non-onset regions of speech separately. Our results show that continuous speech with additional pauses inserted between words significantly increases the speech envelope reconstruction correlations compared to using natural speech, in both the delta and theta frequency bands. It also appears that these increase in speech envelope reconstruction are dominated by the onset regions in the speech envelope. Introducing pauses in speech stimuli has potential clinical benefit for increasing auditory evoked response detectability, though with the disadvantage of speech sounding less natural. The strong effect of pauses and onsets on the decoder should be considered when comparing results from different speech corpora. Whether the increased cortical response, when longer pauses are introduced, reflect improved intelligibility requires further investigation.</p
- …
