227 research outputs found

    Mongolian rhapsody: a cultural evening with Galsan Tschinag

    No full text
    An author presentation by Tuvan writer, chieftain, and shaman, Galsan Tschinag, of his book _The Blue Sky_ on October 26, 2006. The novel was translated into English by Malaspina English Professor Katharina Rout, who also acted as interpreter for this event

    Turbulent annular pipe flow in subcritical transition regime: Effect of radius ratio on strcutures

    No full text
    Direct numerical simulations are performed for annular Poiseuille flows with various radius ratios η (= rin/rout) ∈ [0.1, 0.8] in subcritical transition regime of Reτ ∈ [48, 150]. Because the flow system of the annular Poiseuille flow can be regarded as the Hagen-Poiseuille flow (when η ≈ 0) and the plane Poiseuille flow (η ≈ 1), the (dis-)similarity and the connection between them are discussed. We found the occurrences of localized structure like the turbulent puff in the Hagen-Poiseuille flow at low η and of helical wave like the turbulent stripe pattern in the plane Poiseuille flow at high η. The switching point between helical wave and localized structure by changing η is caught in the region η ∈ [0.1, 0.3]

    Structured electronic design of high-pass ΣΔ converters and their application to cardiac signal acquisition

    No full text
    Achieving an accurate sub-Hz high-pass (HP) cutoff frequency and simultaneously a high accuracy of the transfer function is a challenge in the implementation of analog-to-digital converters for biomedical ExG signals. A structured electronic design approach based on state-space forms is proposed to develop HPΣΔ modulators targeting high accuracy of the HP cutoff frequency and good linearity. Intermediate transfer functions are mathematically evaluated to compare the proposed HPΣΔ topologies with respect to dynamic range. Finally, to illustrate the design method, an orthonormal HPΣΔ modulator is designed to be implemented in 0.18 μm technology which achieves a linearity of 12-bits.Accepted author manuscriptBio-Electronic

    High-Pass ΣΔ Converter Design Using a State-Space Approach and Its Application to Cardiac Signal Acquisition

    No full text
    Cardiac signal acquisition with high linearity and accuracy of the high-pass cut-off frequency imposes a challenge on the implementation of the analog preprocessing and the analog-to-digital converter. This paper describes a state-space-based methodology for designing high-pass sigma-delta (HP Sigma \Delta topologies with high linearity, targeting high accuracy of the high-pass cut-off frequency. Intermediate functions are evaluated mathematically to compare the proposed HP \Sigma \Delta topologies with respect to dynamic range. A sensitivity performance analysis of the noise transfer function with respect to integrator nonidealities and coefficient variations is also described. Finally, to illustrate the design approach, an orthonormal HP \Sigma \Delta modulator is designed to be implemented in 0.18 \mum CMOS technology, is tested with real prerecorded ECG signals.Accepted author manuscriptBio-Electronic

    moving panorama: or Spring Garden rout

    No full text
    No description availabl

    Primary teachers’ perspectives on implementing the inclusion agenda

    No full text
    From book; Inclusive Education: Perspectives on pedagogy, policy and practice. Brown, Z. (ed).Inclusion in primary education is seen as an ideological concept where mainstream educated children in the UK will one day be included in every aspect of the schooling experience. The chapter suggests that inclusion is not the only priority agenda and investigates how it can be practically implemented alongside the government-imposed standards agenda. The author offers a historical account of the simultaneous development of these agendas, including the implementation of the National Curriculum, SATs and league tables. In the second section the author details findings from her recent study and suggests that standards objectives dominate the inclusion agenda in primary schools, and that inclusion is limited to focusing on children with Special Educational Needs

    A generic approach to a rout guidance strategy

    No full text
    The thesis presents a generic methodology able to generate optimal controlled dynamic prescriptive route guidance to be disseminated by means of variable message signs (VMS). The methodology is generic in the sense it can be used on any network topology, with any number of VMS's, for different scenario's (e.g. recurrent congestion or accidents), based on a flexible user defined objective function and will work as long as feasible route alternatives exist. i The methodology uses a new and for this purpose developed macroscopic model called DSMART (dynamic, 1^^ order, macroscopic, single user class, probit route choice, split vectors) and a customized parallel implemented evolutionary algorithm (EA). By using simulation data from the DSMART model in combination with customized mutation operators in the EA, VMS settings are generated in a smart way to increase convergence speed. A prototype ofthe methodology has been developed in Matlab and applied in a case study to the city of Rotterdam in the Netherlands by using a network representation (approx. 500 links) of the motorway with six different VMS's and the connected urban network. The case study illustrated the generic nature by successfully optimizing all three different scenarios ranging from the: everyday recurrent morning congestion, a simulated accident and an extreme event (football final match) by generating a dynamic set of VMS settings for all six instances. As a measure for optimization, the objective function was utilized to express tlie generalized gross travei time \N[)\ch led to a system optimal assignment. To implement the methodology, a rolling horizon control framework is suggested including a crude scenario manager This suggested type of scenario management could be able to reduce the usually astronomical high number of scenarios needed in other systems, to a workable amount. Based upon expected efficiency increase when professionally implemented in the suggested rolling horizon implementation, it is expected that optimal controlled VMS settings could be calculated online for the case study network.Transport & PlanningCivil Engineering and Geoscience

    An evaluation of the infection control potential of a UV clinical podiatry unit

    No full text
    Background: Infection control is a key issue in podiatry as it is in all forms of clinical practice. Airborne contamination may be particularly important in podiatry due to the generation of particulates during treatment. Consequently, technologies that prevent contamination in podiatry settings may have a useful role. The aims of this investigation were twofold, firstly to determine the ability of a UV cabinet to protect instruments from airborne contamination and secondly to determine its ability to remove microbes from contaminated surfaces and instruments. Method: A UV instrument cabinet was installed in a University podiatry suite. Impact samplers and standard microbiological techniques were used to determine the nature and extent of microbial airborne contamination. Sterile filters were used to determine the ability of the UV cabinet to protect exposed surfaces. Artificially contaminated instruments were used to determine the ability of the cabinet to remove microbial contamination. Results: Airborne bacterial contamination was dominated by Gram positive cocci including Staphylococcus aureus. Airborne fungal levels were much lower than those observed for bacteria. The UV cabinet significantly reduced (p < 0.05) the observed levels of airborne contamination. When challenged with contaminated instruments the cabinet was able to reduce microbial levels by between 60% to 100% with more complex instruments e.g. clippers, remaining contaminated. Conclusions: Bacterial airborne contamination is a potential infection risk in podiatry settings due to the presence of S. aureus. The use of a UV instrument cabinet can reduce the risk of contamination by airborne microbes. The UV cabinet tested was unable to decontaminate instruments and as such could pose an infection risk if misused. Keywords: Infection control, UV, Bacteria, Fungi, Dermatophytes, Contaminatio

    Analog front-end and algorithm co-design for efficient biosignal acquisition: And its application to cardiac signal monitoring

    No full text
    Cardiovascular diseases (CVDs) claimed 17.9 million lives annually (2019), representing 32% of total deaths, with 85% attributed to heart attacks and strokes worldwide. Atrial fibrillation (AF) is the most frequent type of cardiac arrhythmia that has a worldwide prevalence of 46 million individuals worldwide. The absence of P-waves in the electrocardiogram and irregular heartbeat characterise AF. Although the awareness and diagnostic methods of AF have improved over the past years, precision and timely diagnosis are required for effective prevention. Electrophysiological recording serves as the gold standard for diagnosing cardiac abnormalities. There currently exist two major fundamental approaches for monitoring the heart from an electrophysiological point of view. The most common approach is the measurement of the ECG (electrocardiogram), which is recorded on the surface of the human body at specific points. A more recent approach (but less commonly used) is the measurement of the AEG (atrial electrogram), which is recorded on the surface of the human heart with higher spatial resolution than ECG. ECG is a technique used to monitor the heart’s electrical activity non-invasively, whereas AEG is used to obtain more profound and detailed insights into the electrical conduction pathways of the heart invasively. AEGs are used to localize the origin of AF for appropriate treatment. Chapter 2 elaborates on the application, the associated technological challenges, and the existing solutions in the literature concerning cardiac signal acquisition. The first approach (most commonly used) for diagnosing cardiac abnormalities is recording the ECG, with a high signal-to-noise-and-interference ratio and sufficient bandwidth using a single-channel analog front-end. One of the main challenges with acquiring ECG is baseline wandering (BW), which refers to low-frequency variations affecting the baseline of the recorded waveform. BW occurs due to body movement or poor contact between the body surface and electrodes. The impact of BW on the ECG signal quality can be twofold: (a) Saturation of the CMOS analog front-end leading to loss of information, and (b) Distortion of the ECG waveform leading to misdiagnosis. In order to prevent or suppress the impact of BW on the ECG waveform, the analog front-end requires a high-pass filter with high linearity and accuracy to minimize distortion. The information in an ECG signal lies between 0.5-200 Hz. Implementing a filter cutoff in the sub-Hz region while maintaining high linearity and accuracy is challenging. Sub-Hz filter implementation translates to large area occupation on silicon and is thus expensive. Although there are several techniques to realize large time constants on-chip, there does not exist a highly linear high-pass transfer characteristic for Sigma-Delta (ΣΔ) analog-to-digital converters (ADCs). The first part of the thesis addresses the implementation of large time constants with high linearity and accuracy. Chapter 3 of the thesis focuses on the design and analysis of a high-pass ΣΔ (HPΣΔ) analog-to-digital converter (ADC) that aims to achieve high linearity for the high-pass (HP) filter cut-off. State-space topologies, commonly used for optimizing filters, are proposed for developing the HPΣΔ modulator topologies. A ΣΔ modulator can be represented as a linear model that consists of integrators and a quantizer, with the quantization noise modeled as additive white noise. By employing the state-space synthesis method, it becomes possible to develop arbitrary transfer functions for the signal and quantization noise of the state-space ΣΔ topologies. The dynamic range of the ΣΔ topology is optimized by signal and noise scaling. Through sensitivity analysis, the impact of coefficient variations in the different integrators on the overall performance and stability of the modulator is determined. Comparative analysis reveals that the orthonormal ΣΔ modulator outperforms the observable canonical statespace- based topology. The experimental results demonstrate that the orthonormal HPΣΔ ADC achieves a figure of merit (FoM) of 5.35 pJ/conv while occupying an area of 0.126 mm2. The orthonormal HPΣΔ ADC also achieves a peak SNDR of 69.8 dB, corresponding to 11.3 bits of ENOB for a signal bandwidth of 3 kHz. The second approach (and less commonly used) for diagnosing cardiac abnormalities is recording the AEG, targeting high spatial resolution using a multi-channel analog frontend. The primary difficulties encountered when acquiring multiple inputs are associated with a proportional increase in area, power consumption, and the number of outgoing wires. In order to mitigate the resource requirements and develop a compact solution for the multi-input system, channel-sharing techniques such as time-division multiplexing, frequency-division multiplexing, and code-division multiplexing (CDM) can be effectively incorporated. These techniques enable the efficient utilization of shared resources, optimizing the overall performance and reducing the system’s complexity. CDM offers enhanced capacity by enabling multiple users to effectively share the same frequency band. It improves signal quality by effectively suppressing interference and band-limited noise, resulting in higher fidelity and more reliable transmission. The second part of this thesis (Chapter 4) focuses on acquiring multi-input AEG signals using CDM. It presents a systematic classification of modulation strategies based on their degrees of freedom to identify suitable techniques for analog signal acquisition. This work also introduces a design method for creating efficient spread-spectrum analog front-ends. Based on the proposed design strategy, spread-spectrum codes can be selected for a given application requirement (high or low-resolution acquisition). The modulation frequency and code length can be determined for optimal performance for the total number of inputs. A 4- input spread-spectrum recording system fabricated in a 0.18 m CMOS process validates the proposed design method. With a 7-bit Gold code generator ( = 127), the maximum achievable crosstalk performance is -40 dB, and the thermal noise density of the system is 224 nV/ √(Hz). The system includes shared components such as an amplifier, an analogto- digital converter (ADC), and an on-chip Gold code generator, with a compact footprint and low power consumption per channel input of 0.067mm2 and 23A, respectively. Recording AEGs using a high-density array of flexible electrodes leads to generating large amounts of data. A significant amount of area (for storage) and power (for data transmission) are required to handle the data. A custom-fabricated flexible multi-electrode array that contains 192 electrode sites is used to acquire the AEGs. Nine such sections are required to cover the entire area of an average adult heart. Chapter 5 focuses on the compressibility of AEGs. Standard compressed sensing is typically used to reduce the data using sub-Nyquist domain sampling on-chip and reconstruction using optimal algorithms off-chip. Signal statistics are not taken into account in standard CS. Both standard and rakeness-based compressed-sensing are applied on atrial electrograms for data compression in this thesis. Rakeness-based compressed-sensing (CS), which uses the signal statistics of the known input signal, is proposed for compressing AEGs. Incorporating signal statistics in the random matrix in rakeness CS leads to better reconstruction performance at higher compression ratios. A similarity analysis is also conducted to quantitatively assess the quality of the reconstructed AEGs during sinus rhythm (SR) and atrial fibrillation. Also, a team of clinicians has visually inspected the reconstructed waveforms to check their suitability for generating an activation map (to map the wavefront of the signal that propagates through the heart). From the survey, it is found that for SR AEG signals up to a compression ratio (CR) of 4.26, the signal is considered clean. However, at CR = 5.1, it becomes noisier but remains suitable for specific applications. In contrast, AF AEG signals exhibit a faster decline in signal quality at higher CRs, attributed to increased activity and distinctive features of AF signals. Even at CR = 5.1, the signal can be used to estimate local activation times but lacks detail for comprehensive feature computation. In summary, this thesis addresses numerous pivotal challenges, namely enhancing the linearity and accuracy of the HP filter cut-off for single-channel cardiac signal acquisition and maximizing resource efficiency for multi-channel cardiac acquisition. We have taken steps towards designing compact application-specific integrated circuits (ASICs) for recording and diagnosing cardiac abnormalities, such as AF. Understanding the underlying biological mechanisms through recording AEGs is crucial for early detection and monitoring of such conditions, which can significantly affect the course of disease progression.Bio-Electronic
    corecore