    Mathematical Modelling of Thermal Process to Aquatic Environment with Different Hydrometeorological Conditions

    Get PDF
    This paper presents the mathematical model of the thermal process from thermal power plant to aquatic environment of the reservoir-cooler, which is located in the Pavlodar region, 17 Km to the north-east of Ekibastuz town. The thermal process in reservoir-cooler with different hydrometeorological conditions is considered, which is solved by three-dimensional Navier-Stokes equations and temperature equation for an incompressible flow in a stratified medium. A numerical method based on the projection method, divides the problem into three stages. At the first stage, it is assumed that the transfer of momentum occurs only by convection and diffusion. Intermediate velocity field is solved by fractional steps method. At the second stage, three-dimensional Poisson equation is solved by the Fourier method in combination with tridiagonal matrix method (Thomas algorithm). Finally, at the third stage, it is expected that the transfer is only due to the pressure gradient. Numerical method determines the basic laws of the hydrothermal processes that qualitatively and quantitatively are approximated depending on different hydrometeorological conditions

    Numerical Study of Discharged Heat Water Effect on Aquatic Environment From Coastal Thermal Power Plant by Using Two Water Discharged Pipes

    No full text
    The article presents a numerical study of the thermal load on the aquatic environment by using two water discharge pipes under various operational capacities of thermal power plant. It is solved by the Navier-Stokes and temperature transport equations for an incompressible fluid in a stratified medium. The aim of this article is to improve the existing water discharge system for reduce the heat load on the reservoir-cooler of the thermal power plants operation (Ekibastuz SDPP-1). In this article, thermal pollution using only two water discharge pipes, using the existing one and building only one additional in the eastern part of the reservoir-cooler is numerically simulated. The numerical method is based on the projection method, which was approximated by the finite volume method. The obtained numerical results of three-dimensional stratified turbulent flow for two water discharge pipes under various operational capacities of the thermal power plant were compared with experimental data and with the numerical results for one water discharge pipe.</jats:p

    Numerical Study of the Discharged Heat Water Effect on the Aquatic Environment from Thermal Power Plant by using Two Water Discharged Pipes

    No full text
    Abstract The paper presents a numerical study of the discharged heat water effect on the aquatic environment from the thermal power plant by using two water discharged pipes. It is solved by the Navier–Stokes and temperature transport equations for an incompressible fluid in a stratified medium. The aim of this study is to improve the existing water discharge system to reduce the heat load on the reservoir-cooler of the thermal power plants operation (Ekibastuz SDPP-1). In this study thermal pollution to the reservoir-cooler using only two water discharged pipes as so using the existing one and building only one additional in the eastern part of the reservoir-cooler is numerically simulated. The numerical method is based on the projection method which was approximated by the finite volume method. The numerical solution of the equation system is divided into four stages. The algorithm is parallelized on a high-performance computer. The obtained numerical results of three-dimensional stratified turbulent flow for two water discharged pipes of the thermal power plant were compared with experimental data and with numerical results for one water discharged pipe. General thermal load in the reservoir-cooler decreases comparing one water discharged pipe and revealed qualitatively and quantitatively approximately the basic laws of hydrothermal processes occurring in the reservoir-cooler can be seen that from numerical simulations where two water discharged pipes were used.</jats:p